4 - 1 0
Section 4
iVIZION® Series Next-Generation Banknote Acceptor Unit
Disassembly/Reassembly
4. Remove the four (4) CIS Sensor Mounting
Screws (See Figure 4-35 a
1
through a
4
), and
remove the CIS Sensor (See Figure 4-35 b) and
the CIS FPC Cable (See Figure 4-35 c) off of the
Lower Validation Section.
5. Remove two (2) mounting screws (See Figure 4-
35 d
1
& d
2
), retaining the Lower UV Sensor in
place (See Figure 4-35 e) and remove it and the
Lower UV FFC Cable (See Figure 4-35 f) from
the Lower Validation Section.
Validation Unit Timing Belt Removal
To remove Timing Belt proceed as follows:
1. Remove the three (3) Side Plate Cover Mounting
Screws (See Figure 4-36 a
1,
a
2
& a
3
) located on
right side of the Lower Validation Section.
2. Remove the Cover (See Figure 4-36 b) from the
Lower Validation Section.
3. Remove Timing Belt (See Figure 4-36 c) from the
Lower Validation Section.
Reassembly Cautions
When reassembling the Upper/Lower UV Sensors,
make sure that both of the Sensor positions and
directions are correctly placed. Match the Connec-
tor’s position as illustrated in Figure 4-38a.
Disassembly and Reassembly of the iVIZION
®
Unit is now complete.
NOTE: If foreign objects are observed
adhering to the CIS surface, blow it clean
by using a Compressed Air spray.
Figure 4-35
CIS, CIS FPC, Lower UV Sensor &
Lower UV FFC Removal
d
1
d
2
a
1
a
2
a
3
a
4
b
c
e
f
NOTE: When reassembling the Unit,
ensure that the UV Sensors are correctly
re-positioned and set in place as illustrated
NOTE: Follow the same procedure to
remove the opposite side Timing Belt.
Figure 4-36
Timing Belt Removal
a
1
a
2
a
3
b
c
NOTE: The Timing Belt should be
reinstalled as illustrated by the
Blue
path
shown in Figure 4-37 when the Unit is
being reassembled.
Figure 4-37
Timing Belt Replacement
Figure 4-38
Upper/Lower UV Sensors Location
a
a
[Upper]
[Lower]
NOTE: Ensure that all Sensors and the
iVIZION
®
BG 85B Head surfaces are
absolutely clean before reassembling the
iVIZION
®
Unit. Also ensure that all Finger
Prints, smudges, dirt or film that exists on
any surfaces in the Transport path are
removed.