4. Controlled by universal DMX-controller:

When the units are connected in DMX-mode, they can be controlled using the following DMX-charts:

1 CHANNEL MODE

4 CHANNEL MODE

What are patterns?

Patterns are different static (non moving) combinations of LEDs.
When the value of CH1 is set between 000 and 119, you can use CH2 to select 25 different patterns.
Use CH3 to change the strobe frequency of the selected patterns.

What are chases?

Chases are a series of patterns put in a loop to create dynamic (moving) effects.
When the value of CH1 is set between 120 and 239, you can use CH2 to select 25 different chases.
Use CH3 to change the speed of the selected chases.

MAINTENANCE

Make sure the area below the installation place is free from unwanted persons during servicing.

Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.

During inspection the following points should be checked:

All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.

Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.

When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.

In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.

The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

Clean with a soft cloth using normal glass cleaning products.

Always dry the parts carefully.

Clean the external optics at least once every 30 days.

Clean the internal optics at least every 90 days.

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

6/36

LEDFLOWER DMX

SPECIFICATIONS

Mains Input:

AC 100V ~ 240V, 50/60Hz

Fuse:

250V 2A slow blow (20mm glass)

Sound Control:

Internal microphone

DMX connections:

3pin XLR male / female

DMX channels used:

1 or 4 channels

Lamp:

52 LEDs (R=16 + G=12 + B=12 + W=12)

Size:

236 x 141 x 203 mm

Weight:

2kg

Every information is subject to change without prior notice

You can download the latest version of this user manual on our website: www.beglec.com

Summary of Contents for LED FLOWER DMX - V2.0

Page 1: ......

Page 2: ...s normas vigentes no seu pa s WARNING DANGER never expose the lens to direct sunlight even for a short period This may damage the light effect or even cause fire ATTENTION DANGER n exposez jamais la l...

Page 3: ...ide the unit Electric shock or malfunction may result If a foreign object enters the unit immediately disconnect the mains power Locate the fixture in a well ventilated spot away from any flammable ma...

Page 4: ...l safety in your country Electrical installation in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and...

Page 5: ...o cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order to protect the device...

Page 6: ...mation de condensation l int rieur de l appareil patientez quelques minutes pour laisser l appareil s adapter la temp rature ambiante lorsqu il arrive dans une pi ce chauff e apr s le transport La con...

Page 7: ...ement un c ble de s curit qui peut supporter 12 fois le poids de l appareil lors de l installation Ce c ble de s curit secondaire doit tre install de mani re ce qu aucune partie de l appareil ne puiss...

Page 8: ...e entre 120 et 239 on peut utiliser le CH2 pour s lectionner 25 effets chenillards diff rents On utilise le CH3 pour modifier la vitesse des effets chenillards s lectionn s MAINTENANCE Assurez vous q...

Page 9: ...oneren Het kan soms zelfs schade aan het apparaat toebrengen Gebruik dit apparaat uitsluitend binnenshuis Plaats geen stukken metaal en mors geen vocht binnen in het toestel om elektrische schokken of...

Page 10: ...veiligheid en de technische mechaniek door een expert zijn goedgekeurd alvorens ze voor de eerste keer te gebruiken Elk jaar moeten de installaties worden gekeurd door een vakman om te controleren of...

Page 11: ...ijn en mogen niet verroest zijn Behuizingen vastzetstukken installeringplaatsen plafond spanten schokbrekers mogen absoluut niet verwrongen zijn Wanneer een optische lens klaarblijkelijk beschadigd is...

Page 12: ...h ausgeschaltet stehen lassen Kondensation kann zu Leistungsverlust des Ger ts oder gar Besch digung f hren Ger t nicht im Freien und in feuchten R umen und Umgebungen verwenden Keine Metallgegenst nd...

Page 13: ...um intelligente Lichtsysteme zu steuern Sie m ssen Ihren DMX Controller und alle angeschlossenen Ger te mit einem hochwertigen symmetrischen Kabel hintereinander schalten daisy chain Es werden sowohl...

Page 14: ...sichtbar besch digt Spr nge oder tiefe Kratzer dann m ssen die entsprechenden Teile ausgewechselt werden Netzkabel muss stets in einwandfreiem Zustand sein und selbst bei kleinsten Besch digungen ern...

Page 15: ...peratura exterior cuando la lleve a una habitaci n c lida despu s del transporte A veces la condensaci n impide que la unidad funcione a pleno rendimiento y puede incluso provocar da os Esta unidad s...

Page 16: ...alentamiento de la unidad El operario debe asegurarse de que las instalaciones relacionadas con la seguridad son aprobadas por un experto antes de utilizarlas por primera vez Las instalaciones deber n...

Page 17: ...Use CH3 para cambiar la velocidad de las orugas seleccionadas MANTENIMIENTO Aseg rese de que debajo de la zona del lugar de instalaci n no haya personas durante el mantenimiento Apague la unidad dese...

Page 18: ...mente a utiliza o em espa os fechados N o introduza objectos de metal nem verta l quidos no interior do produto correr risco de choque el ctrico ou poder danificar o produto Caso algum objecto estranh...

Page 19: ...ertificar se que a seguran a est assegurada PORTUGU S MANUAL DO UTILIZADOR JB SYSTEMS 34 36 LEDFLOWER DMX INSTALA O EL CTRICA CONFIGURA O Importante A instala o el ctrica deve ser feita apenas por pes...

Page 20: ...estar apertados firmemente e n o poder o estar corro dos A cobertura da unidade os pontos de fixa o e as reas de instala o tecto arma o etc n o dever o apresentar qualquer deforma o Caso uma lente ap...

Reviews: