background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

3/36

LEDFLOWER DMX

DESCRIPTION:

1. Fuse holder
2. ¼” jack used to connect the optional CA-8

controller.

3. DMX input: 3pin male XLR-connector used to

connect

universal

DMX-cables.

This

input

receives instructions from a DMX-controller or
from another unit when used in master/slave
mode.

4. DMX output: 3pin female XLR-connector used to

connect the LEDFLOWER DMX with the next
unit in the DMX chain or with another
LEDFLOWER DMX when used in master/slave
mode.

5. Internal microphone
6. Earth connection
7. Mains cable
8. Hanging bracket with 1 knob to fasten the unit

and a mounting hole to fix a mounting hook.

9. DIP switches, used to set the DMX-starting address of the unit.

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 50cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

ELECTRICAL INSTAL ADDRESSING

Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.

Electrical installation in DMX-mode:

The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
“daisy chain” your DMX controller and all the connected units with a good quality balanced cable.

Both XLR-3pin and XLR-5pin connectors are used, however XLR-3pin is more popular because these
cables are compatible with balanced audio cables.
Pin layout XLR-3pin:

Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)

Pin layout XLR-5pin:

Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+) ~ Pins4+5 not used.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/36

LEDFLOWER DMX

To prevent strange behavior of the light effects, due to interferences, you must use
a 90

Ω

to 120

Ω

terminator at the end of the chain. Never use Y-splitter cables, this

simply won’t work!

Make sure that all units are connected to the mains.

Each light effect in the chain needs to have its proper starting address so it knows
which commands from the controller it has to decode. In the next section you will learn how to set the
DMX addresses.

How to set the DIP-switches to obtain the right starting address:

Each of the first 9 DIP-switches correspond to a certain DMX-value:

DIP

#1

#2

#3

#4

#5

#6

#7

#8

#9

#10

Value

1

2

4

8

16

32

64

128

256

OFF = 4CH DMX mode

ON = 1CH DMX mode

You can combine the values of these switches to become any starting address between 1 and 512:
Begin address = 01

switch 1=ON

values: 1

Begin address = 05

switch 1+3=ON

values: 1+4 = 5

Begin address = 09

switch 1+4=ON

values: 1+8 = 9

Begin address = 13

switch 1+3+4=ON

values: 1+4+8 = 13


Begin address = 62

switch 2+3+4+5+6=ON

values: 2+4+8+16+32 = 62

CONTROLLING THE LEDFLOWER DMX

1. Standalone 1unit:
Important: The DMX address MUST be set to 001.

(first DIP switch = ON, all other are OFF)

Just connect the unit to the mains and put on some music. The unit will start working automatically to the
rhythm of the music.

2. Two or more units in master/slave setup:

Connect 2 to maximum 16 units together using good quality balanced XLR microphone cables. The unit that
has no cable connected to its input will react as master, the others are the slave units.

Important: On the master unit the DMX address MUST be set to 001.

(first DIP switch = ON, all other are

OFF)

The slave units can have any DMX address value but NOT 001!

3. Connect the optional CA-8 controller for more control:

The CA-8 controller can only be used in standalone or master/slave mode. Connect the
controller to the jack input of the first unit (master). Now you can control all the connected
units:

STAND BY

Blackout the unit

FUNCTION

1. Strobe in white color
2. Sound strobe

Toggle between 10 different chases

MODE

Strobe / Sound (LED off)

Chase (LED ON)

Summary of Contents for LED FLOWER DMX - V2.0

Page 1: ......

Page 2: ...s normas vigentes no seu pa s WARNING DANGER never expose the lens to direct sunlight even for a short period This may damage the light effect or even cause fire ATTENTION DANGER n exposez jamais la l...

Page 3: ...ide the unit Electric shock or malfunction may result If a foreign object enters the unit immediately disconnect the mains power Locate the fixture in a well ventilated spot away from any flammable ma...

Page 4: ...l safety in your country Electrical installation in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and...

Page 5: ...o cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order to protect the device...

Page 6: ...mation de condensation l int rieur de l appareil patientez quelques minutes pour laisser l appareil s adapter la temp rature ambiante lorsqu il arrive dans une pi ce chauff e apr s le transport La con...

Page 7: ...ement un c ble de s curit qui peut supporter 12 fois le poids de l appareil lors de l installation Ce c ble de s curit secondaire doit tre install de mani re ce qu aucune partie de l appareil ne puiss...

Page 8: ...e entre 120 et 239 on peut utiliser le CH2 pour s lectionner 25 effets chenillards diff rents On utilise le CH3 pour modifier la vitesse des effets chenillards s lectionn s MAINTENANCE Assurez vous q...

Page 9: ...oneren Het kan soms zelfs schade aan het apparaat toebrengen Gebruik dit apparaat uitsluitend binnenshuis Plaats geen stukken metaal en mors geen vocht binnen in het toestel om elektrische schokken of...

Page 10: ...veiligheid en de technische mechaniek door een expert zijn goedgekeurd alvorens ze voor de eerste keer te gebruiken Elk jaar moeten de installaties worden gekeurd door een vakman om te controleren of...

Page 11: ...ijn en mogen niet verroest zijn Behuizingen vastzetstukken installeringplaatsen plafond spanten schokbrekers mogen absoluut niet verwrongen zijn Wanneer een optische lens klaarblijkelijk beschadigd is...

Page 12: ...h ausgeschaltet stehen lassen Kondensation kann zu Leistungsverlust des Ger ts oder gar Besch digung f hren Ger t nicht im Freien und in feuchten R umen und Umgebungen verwenden Keine Metallgegenst nd...

Page 13: ...um intelligente Lichtsysteme zu steuern Sie m ssen Ihren DMX Controller und alle angeschlossenen Ger te mit einem hochwertigen symmetrischen Kabel hintereinander schalten daisy chain Es werden sowohl...

Page 14: ...sichtbar besch digt Spr nge oder tiefe Kratzer dann m ssen die entsprechenden Teile ausgewechselt werden Netzkabel muss stets in einwandfreiem Zustand sein und selbst bei kleinsten Besch digungen ern...

Page 15: ...peratura exterior cuando la lleve a una habitaci n c lida despu s del transporte A veces la condensaci n impide que la unidad funcione a pleno rendimiento y puede incluso provocar da os Esta unidad s...

Page 16: ...alentamiento de la unidad El operario debe asegurarse de que las instalaciones relacionadas con la seguridad son aprobadas por un experto antes de utilizarlas por primera vez Las instalaciones deber n...

Page 17: ...Use CH3 para cambiar la velocidad de las orugas seleccionadas MANTENIMIENTO Aseg rese de que debajo de la zona del lugar de instalaci n no haya personas durante el mantenimiento Apague la unidad dese...

Page 18: ...mente a utiliza o em espa os fechados N o introduza objectos de metal nem verta l quidos no interior do produto correr risco de choque el ctrico ou poder danificar o produto Caso algum objecto estranh...

Page 19: ...ertificar se que a seguran a est assegurada PORTUGU S MANUAL DO UTILIZADOR JB SYSTEMS 34 36 LEDFLOWER DMX INSTALA O EL CTRICA CONFIGURA O Importante A instala o el ctrica deve ser feita apenas por pes...

Page 20: ...estar apertados firmemente e n o poder o estar corro dos A cobertura da unidade os pontos de fixa o e as reas de instala o tecto arma o etc n o dever o apresentar qualquer deforma o Caso uma lente ap...