CONTROL PANEL
-
FUNCTIONS
Wired (Foot pedal / hand
-
held) Remote Control
A 9 pin remote control socket is fitted as standard to the front panel of the machine,
see pages 78/79 for optional remote controls)
1)
Before welding, press the remote
-
control function
button to enable the remote
control function.
2) The indicator
will be lit indicating that the remote
-
control function is enabled.
If the remote controller is connected, the remote control device controls the welding current.
If no remote controller is connected then the welding current is controlled by the panel control dial.
3) If the indicator
is not lit, this indicates that the remote
-
control function is not active and welding
current is controlled by the front panel control dial.
Wireless Remote Control (optional)
(Wireless remote control interface is optional, see pages 78/79 for remote options)
1)
Wireless pairing connection
Before welding, press and hold the panel remote control function button
and
the pairing button
of the wireless remote controller at the same time, hold for 2 seconds to perform
wireless remote control pairing.
During pairing, the blue indicator of wireless receiver module
flashes, after successful pairing, the
indicator of remote control mode is on .
At the same time the blue indicator of wireless receiver module
will be constant on and the welder
display window displays "OK".
After successful pairing, the welding current can be adjusted by "+" or "
-
" buttons on the wireless
remote controller.
The range of current is from the machines minimum to the maximum current value which was previously
displayed as preset current on the panel.
2) Disconnecting the wireless connection
After the remote controller is successfully paired, press the remote control function button
on the
panel or the pairing button
of the wireless remote controller for 2 seconds, and the wireless
connection of the remote controller will be disconnected.
After disconnecting the display window of the welder displays the character "FAL", and the green
indicator of the wireless receiver module
will be constantly on.