CONTROL PANEL
-
FUNCTIONS
Configuration Settings (Engineers mode)
Restore Factory Settings
To reset to factory settings for the EM
-
200CT or the EM
-
250CT,
press and hold the welding mode button
for 5 seconds to
restore all factory settings.
After holding the button for 1 second the display window will
show the start of a count down from 3 to zero.
When the countdown ends, the factory settings are restored.
If the button is released before the countdown ends, the restore
will not have taken place.
Factory settings are detailed and shown in the table below.
Welding
Process
Parameter
Restored Parameter
Value
EVO EM
-
200CT
Restored Parameter
Value
EVO EM
-
250CT
MIG
parameters
Burn back time
0.2S
0.2S
Burn back voltage
13V
13V
Inductance
0
0
Pre
-
flow time
0.1S
0.1S
Post
-
flow time
0.5S
0.5S
Welding voltage
19.0V
19.0V
Wire feeding speed
5m/min
5m/min
Crater voltage
19.0V
19.0V
Crater feeding speed
5m/min
5m/min
MMA
parameters
Arc
-
force current
40A
40A
Hot start current
30A
30A
Welding current
130A
130A
Lift TIG
parameters
TIG downslope time
0.5S
0.5S
Welding current
100A
100A