![Jasic EVO 2.0 EM-200CT Operator'S Manual Download Page 17](http://html1.mh-extra.com/html/jasic/evo-2-0-em-200ct/evo-2-0-em-200ct_operators-manual_3440941017.webp)
17
INSTALLATION
Input Power Connection continued
1.
Test with multi
-
meter to ensure the input voltage value is within the specified input voltage range.
2.
Ensure that the power switch of the welder is turned off.
3.
Wire the input mains cable wires to the correct sized mains plug, ensuring that the live, neutral and
earth (ground) wires are connected correctly.
4.
Carry out an electrical test of the machine if required (i.e. PAT test).
5.
Ensure that the input fuse is correctly rated for the machine.
6.
Connect the machine mains power plug firmly to the corresponding supply socket.
Please Note!
If the machine needs to be operated on long extension leads, then please use an extension
lead where the cable has a larger cross
-
sectional area to reduce the voltage drop.
Please consult your electrician or electrical supplier for the recommended size.
Gas Connections
The gas regulator is designed to reduce and control the high pressure gas from a
cylinder or pipeline to the working pressure required for the Jasic TIG machine.
Before fitting the regulator, clean the cylinder valve outlet.
Match the regulator to cylinder and before connecting, ensure
the regulator and the regulator inlet and cylinder outlet
match. Connect the regulator inlet connection to cylinder
and tighten it firmly (do not overtighten) with a suitable
spanner. If using a gas flowmeter, connect to the regulator
outlet. Connect the gas hose to the regulator/flowmeter
which is now located on the shield gas cylinder and connect
the other end to the gas socket on the machines rear panel.
With the regulator connected to cylinder, always stand
to one side of regulator and only then slowly open the
cylinder valve. Slowly turn adjusting knob in (clockwise) direction
until the outlet gauge indicates that you have set the required flow rate.
To reduce the gas flow rate, turn the adjustment knob anti
-
clockwise, until the required flow rate is
Indicated on the gauge/flow meter.
Output Power Connections
When inserting the cable plug of the work return lead, MMA electrode holder or TIG torch adapter into
the dinse socket on the front panel of the welding machine, rotate it clockwise to tighten.
It is very important to check
these power connections daily
to ensure they have not
become loose otherwise arcing
may occur when used under load.