![Jasic EVO 2.0 EM-200CT Operator'S Manual Download Page 25](http://html1.mh-extra.com/html/jasic/evo-2-0-em-200ct/evo-2-0-em-200ct_operators-manual_3440941025.webp)
25
CONTROL PANEL
-
SETTINGS
Configuration Settings
Welding Engineers Mode functions
The Welding Engineer Mode function allows users to adjust and
Set background default parameters or functions as follows:
Press and hold the top parameter adjustment knob
for 5s in startup state.
After pressing and holding the top parameter adjustment
knob" for 2s, the machine will count down from 3s; at the end of
the countdown, the top display window will display a parameter
number, such as "F01" and the bottom parameter display will
show a value corresponding to that number.
Rotating the top parameter adjustment dial will allow you to select
the parameter number to set the back
-
end parameter default
value or function.
Rotating the bottom parameter adjustment dial will set the value corresponding to that parameter
number. Pressing the top parameter adjustment dial will to save the new value.
After setting the value, press the welding mode selection key
to exit welding engineers mode.
Refer to the following table for the parameter numbers, function definitions and configuration values
Upon selecting your chosen response time, press the control dial to save the current settings.
Then press the welding mode button to complete the operation and exit.
Background
function
Parameter
no.
Default
value
Function definition
Standby time
adjustment
function
F01
10
Can be set to four values: "0", "5", "10" or "15".
"0" indicates that the standby function is disabled and the
machine will not enter standby state.
"5", "10" and "15" indicate that the standby function is
enabled and the machine will enter the standby state after
the corresponding time in minutes.
Input
overvoltage/
undervoltage
protection
F02
0
Can be set to "0" or "1".
"0" indicates that the overvoltage/undervoltage protection
function is disabled and OFF.
"1" indicates that the overvoltage/undervoltage protection
function is enabled and active.
Pre
-
flow time
F03
MIG: 0.1
Lift TIG: 0.5
Setting Pre
-
flow time for either MIG or Lift TIG will depend
on which welding mode you are in when entering Welding
Engineer Mode.
If the "Welding Mode" is MIG, set the MIG pre
-
flow time,
with range 0 ~ 2.0, adjustments of 0.1 and unit in seconds.
If the "Welding Mode" is Lift TIG, set the Lift TIG pre
-
flow
time, with range 0 ~ 5.0, accuracy of 0.5, and unit of
seconds.
Summary of Contents for EVO 2.0 EM-200CT
Page 1: ...1 ...
Page 74: ...74 UKCA Declaration of Conformity ...
Page 75: ...75 EC DECLARATION OF CONFORMITY ...
Page 77: ...77 SCHEMATIC ...
Page 80: ...80 ...