42
Advanced settings menu
The advanced settings are entered only with a service code. This menu is locked due to
safety reasons and can be adjusted only by a credited service partner.
With pressing mix key, start key and down key at startup, you enter
advanced settings menu.
First you can adjust temperature sensors:
With pressing up key value is increased by 1 unit.
With pressing down key value is decreased by 1 unit.
With pressing right key you switch to another setting.
Water sensor
offset adjustments can be made by
increasing or decreasing the current temperature
value. Pay attention on analog value when chan-
ging (seen if key start is pressed).
Milk sensor
offset adjustments can be made by
increasing or decreasing the current temperature
value. Pay attention on analog value when chan-
ging (seen if key start is pressed).
Type of device
can be chosen:
• P100
• P50
Max DIF milk -water
is a temperature difference
between milk and secondary water when device
is in heating phase.
Heater ON
add is a temperature difference of
cooling water and setpoint temperature. When
cooling, secondary water will cool down only for
entered temperature value lower than setpoint
temperature of milk.
Summary of Contents for Milky FJ 50 PF
Page 7: ...7 Bild 1 12 5 9 4 7 1 2 11 Bild 2 13 14 16 15 3 8 10 19 6...
Page 8: ...8 Bild 4 Auslass ist niedriger als Kesselboden Bild 3 PU Isolation 17 18 20 21...
Page 23: ...23...
Page 29: ...29 pic 1 12 5 9 4 7 1 2 11 pic 2 13 14 16 15 3 8 10 19 6...
Page 30: ...30 pic 4 Outlet lower than kettle bottom pic 3 PU foam insulation 17 18 20 21...
Page 45: ...45...
Page 51: ...51 Fig 1 12 5 9 4 7 1 2 11 Fig 2 13 14 16 15 3 8 10 19 6...
Page 52: ...52 pic 4 La sortie est au fond de la chaudi re Fig 3 PU isolation 17 18 20 21...
Page 67: ...67...