Heating procedure
VBefore heating procedure device must be properly connected.
• Place the device on the firm, plain and stable floor. It is recommended that the source of
cooling water and the drain is not more than 2 m away from the device.
• Connect water supply to inlet hose and start filling heating water into secondary coat.
• Connect power supply to electric case.
• Pour desired amount of milk into the device.
• Turn on the device – Turn the main switch on (located on the side of the electric case).
• Heating can begin when device is properly setup – adjust heating temperatures and
holding times.
• Press green button to start the heating process. The red light on the upper left part of
control box is lit, indicating the heating is in progress. The display shows the present tem-
perature and begins to heat till setpoint temperature is reached.
• After set temperature is reached heating transforms to holding, control unit beeps and
the holding time is displayed on screen.
• Pasteurizer switches to next phase automatically when holding time is passed and stops
the process automatically when fourth phase holding time is passed.
•
You can switch the phases if you want, by pressing the start key during operation.
Cover the kettle with lid. If kettle is not covered with lid, the time of heating will be lon-
ger and it will not reach maximal stated temperature!
If you want to move on second process, even if first process is not finished yet, just press
key start.
Cooling procedure
Before cooling procedure device must be properly connected.
• Connect cooling water to cooling water inlet connection
• Connect drain hose to hot water outlet connection.
Slowly open the valve on your water network or cooling tank, that you connected inlet
hose to. Cooling water supply must always be connected to the device, device will open
the flow automatically, when needed. When setpoint temperature of milk will be lower
than current temperature of milk, the device will automatically start the cooling proce-
dure. The blue light on the upper right part of control box is lit, indicating the cooling is
in progress. Cold water will slowly come into the device and out through hot water outlet
connection to the drain. Cooling speed depends on cooling water temperature and flow.
When desired temperature is reached, cold water flow will be automatically stopped by
solenoid valve.
COOLING WATER COMING OUT OF DEVICE IS HOT!
BE CAREFUL THAT HOSE FOR HOT WATER OUTLET IS FREE (IS NOT PRESSED)
Summary of Contents for Milky FJ 50 PF
Page 7: ...7 Bild 1 12 5 9 4 7 1 2 11 Bild 2 13 14 16 15 3 8 10 19 6...
Page 8: ...8 Bild 4 Auslass ist niedriger als Kesselboden Bild 3 PU Isolation 17 18 20 21...
Page 23: ...23...
Page 29: ...29 pic 1 12 5 9 4 7 1 2 11 pic 2 13 14 16 15 3 8 10 19 6...
Page 30: ...30 pic 4 Outlet lower than kettle bottom pic 3 PU foam insulation 17 18 20 21...
Page 45: ...45...
Page 51: ...51 Fig 1 12 5 9 4 7 1 2 11 Fig 2 13 14 16 15 3 8 10 19 6...
Page 52: ...52 pic 4 La sortie est au fond de la chaudi re Fig 3 PU isolation 17 18 20 21...
Page 67: ...67...