Page 7
Section 3. Installation Instructions Model PURE700 and PURE1400
3.1 Materials and Tools
NOTE
Salt not included. See pages 18 - 21.
Installation Materials Furnished
Tools Needed for Installation
(1 ea.)
Electrolytic Cell
(2 ea.)
Cell Union with (2-each) O-Rings and 2” Tee
(1 ea.)
2” to 1½” Reducing Bushing
(1 ea.)
Roll Te
fl
on Tape
(1 ea.)
Flow/Temp/Salinity Sensor with 8 ft (2.44 m) or 16 ft (4.88 m)
cable
(1 ea.)
8 ft (2.44 m) or 16 ft (4.88 m) DC Power Cord
(1 ea.)
Power Supply/Control Center
(4 ea.)
Anchors and Screws
(2 ea.)
Wire Nuts
(1 ea.)
Owner’s Manual - Warranty Information
(1 ea.)
Installation Template
Tape Measure
Phillips & Flathead Screwdrivers
Pliers
Hacksaw
Voltmeter to determine line voltage of AC wiring to power supply
Electric Drill Motor and 1/4 “ masonry drill bit for mounting power supply on
block or stucco wall
An NSF
®
approved All Purpose Cleaner Primer
An NSF
®
approved All Purpose Cement (such as Weld-On 794, 793)
3.2 Plumbing Con
fi
gurations
3.2.1 Recommended Plumbing Con
fi
guration
The preferred installation is that the Sensors and Cell are plumbed in the return line to the pool after
(downstream) all the pool equipment (
fi
lter, heater, solar, etc.). The Cell and Sensor Tee
fi
tting are designed
to be plumbed into 2” PVC pipe. Adapters can be used for systems with 1.5” plumbing. Figures 3 and 4 on
page 8 illustrate the recommended plumbing con
fi
guration, which result in the most reliable operation.
Note
The AquaPure is powered from the LOAD SIDE of the pool circulation pump relay or the time clock. This
ensures that the Cell only operates when the pool pump is ON. The Flow Sensor serves as a protection
device to ensure there is suffi cient fl ow for the cell to operate.
WARNING
When using electrical products, basic precautions should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation or service, ensure that all power to the device is disconnected/turned
off at the circuit breaker. Connect only to a circuit protected by a ground fault circuit-interrupter
(GFCI).
• Grounding is required. The unit should be installed by a qualifi ed service representative and
should be properly grounded. (See Earth Bonding, page 12).
• Install to permit access for servicing.
• Read Cautions and Important Instructions on page 4.
Before attempting any electrical wiring, be
sure to read and follow Safety Instructions. Wiring should only be attempted by a qualifi ed
professional.