Page 22
Figure 16. Control Center Front Panel
Section 5. Operating Instructions
1. Broadcast or Spread Salt into Shallow End of Pool. Do Not Add Salt through
Skimmers, Main Drain or Surge Tank.
2. Set Unit to "00" % for 24 Hours. The AquaPure must read "00" for 24 hours
after the salt has been added and circulated in the pool.
Boost - 24 Hour 100% Chlorine Production Cycle - Refer to Manual
- - - - To Enter Boost Mode Press and Hold "Temperature" Button for 10 Seconds
Pool Temperature - Temperature of Pool Water at Flow Sensor
CELL ON - Making Chlorine
CELL RESTING - Off Portion of Chlorine Production Cycle
FLOW - Water Flow Present
CELL REVERSING - Automatic Cleaning Cycle in Progress
ADD SALT - Salinity Should be 3.0 - 3.5 Grams / Liter
SERVICE - Refer to Manual -
- - - - To Silence Audible Service Alarm Press and Hold "Salinity" Button for 5 Seconds
DIRECTIONS FOR ADDING SALT
Power On
CELL ON
CELL RESTING
FLOW
CELL REVERSING
ADD SALT
SERVICE
CHLORINE
PRODUCTION RATE
C
D
A
B
?
?
Salinity
Pool
Temperature
- Boost -
5.1 Using the Front Panel Controls
NOTE
With the exception of
Boost
, the front panel buttons can not be used when the AquaPure is controlled by the
AquaLink RS. If arrow button
A
or arrow button
B
is pressed,
JA
in the AquaPure display indicates that
the
AquaLink RS is controlling the AquaPure and desired output percentages.
Chlorine Production Rate
(more or less) Adjustment
Pressing the arrow button
A
or arrow button
B
will change the
CHLORINE PRODUCTION
in 1% increments. Generally,
adjustments to production should be made in 10% increments.
Salinity
Press the
Salinity
button
C
to check the salinity of the water in pool.
Boost
Press and hold the
Temperature
button
D
for 10 seconds to enter the
Boost
mode (Note ‘
bo
’ will
fl
ash intermittently).
Boost
can be used to
set chlorine production to maximum (100%) for 24 hours of operation.
After 24 hours of chlorinator run time, chlorine production will return
to previous setting. To clear the
Boost
mode, press and hold the
Temperature
button again for 10 seconds.
NOTE
When a pool pump timer is used to limit chlorinator run time, the 24 hours will only count down when the
clorinator is on.
Temperature
Press
the
Temperature
button
D
to check the pool water temperature.
Temperature measurements can be displayed in either Fahrenheit or
Celsius. For more information, see Section 8,
Temperature Conversion
.
Summary of Contents for AquaPure Pure700