Page 12
2. It is recommended that the Flow/Temp/Salinity Sensor and Electrolytic Cell be installed in the pool
return line after the
fi
lter and heater. Water passes through the Flow/Temp/Salinity Sensor before the
Cell. The Cell can be installed in either a horizontal (as shown in Figure 12) or a vertical position.
3. Position the Flow/Temp/Salinity Sensor Tee and Cell in the recommended position (See Figure 11
Detail A) and (page 5 Figure 1).
4. Locate a suitable section of pipe, approximately 21 inches (533 mm) long. The Flow/Temp/Salinity
Sensor cable and Cell DC cord
must
be able to reach from the control center to this section.
6. Check source voltage. (All units are factory wired for 230 VAC
).
In order to use on 115 VAC, the
internal factory wiring of the control center must be changed. (See wiring diagram page 6
Figure 2).
7. Use #12/3 insulated wire and conduit. Wire control center transformer to pool pump power source.
The control center should be connected to the pump motor switch or automatic timer (Pool Pump
Timer) as shown in the diagram on page 6 Figure 2.
The
fl
ow portion of the Flow/Temp/Salinity
Sensor is a backup device only.
Attach the third wire (
Ground
) from the electrical panel to the ground
point inside the Control Center.
Earth bonding in Section 3.4 must also be accomplished to insure
personal safety and safety of equipment.
3.4 Earth Bonding (Grounding)
A solid, copper # 8 awg (8.4 mm
2
) wire is
recommended
for connecting the control center to a Permanent
Earth Ground connection that is acceptable to the local inspection authority. Refer to your local codes for
the acceptable grounding wire gauge. Attach the bonding point located on bottom of the chassis backplate
to a Common Earth Bonding Point. Do not use the AquaPure as the Common Bonding Point. Each piece
of non-AquaPure related pool equipment requiring a ground should be bonded to the Common, Approved
Earth Bonding Point.
Never ground pool pump to the chassis backplate
.
3.5 Installing the Cell - Flow/Temp/Salinity Sensor for the PURE700 and PURE1400
NOTE:
Maximum operating Pressure is 517 kPa or 75 PSI - Minimum Flow Rate is 20 GPM (76 LPM).
1. Be sure pool pump is turned off.
WARNING
ATTENTION INSTALLER: If The Flow/Temp/Salinity Sensor is not installed properly, it may allow
the Cell to operate without water fl ow. This would cause a buildup of fl ammable gases resulting in a
HAZARDOUS Condition.
•
Mount as shown in Figure 11 Detail A. This will result in the most reliable operation.
•
The Flow/Temp/Salinity Sensor must be mounted:
(1) in the same line as the Electrolytic Cell.
(2) with no valves or diverters between the Flow/Temp/Salinity Sensor and Cell.
(3) preferably between the Pool Pump and the Cell.
•
Do not mount the Flow/Temp/Salinity Sensor as shown in Detail C of Figure 11. This mounting
position can be HAZARDOUS.
•
Anytime the Flow/Temp/Salinity Sensor is connected or disconnected and reconnected, the AC
power to the unit must be turned off and back on (Cycle Power). If power is not cycled, unreliable
operation of the Flow/Temp/Salinity Sensor will result.