Pool Pump Timer
A Pool Pump Timer is not included as part of your AquaPure. It is recommended that
a timer or an AquaLink RS control system be used to save on energy and prolong the
service life of your pool pump and the AquaPure.
2.1 Electrical Speci
fi
cations
Circuit Protection
2 pole 20 AMP device at the Electrical Panel.
Model PURE700 and PURE700-16
Model PURE1400 and PURE1400-16
Input:
115 VAC, 50/60 Hz, 1.5 AMPS
230 VAC, 50/60 Hz, 0.75 AMPS
Input:
115 VAC, 50/60 Hz, 2.5 AMPS
230 VAC, 50/60 Hz, 1.25 AMPS
Output:
22-30 VDC @ 3 AMPS maximum
Output:
22-30 VDC @ 6 AMPS maximum
Chlorine:
0.625 lb. / 24 Hr. (283 gm / 24 Hr.)
Chlorine: 1.25 lb. / 24 Hr. (567 gm / 24 Hr.)
External
Control:
ORP/External Control Connector
AquaLink
®
RS485 Connector
External
Control:
ORP/External Control Connector
AquaLink
®
RS485 Connector
CAUTION
Factory wired for 230 VAC service.
If available electrical service is 115 VAC, the power supply
wiring must be changed to operate on 115 VAC as shown in the wiring diagram below. (Figure 2.)
Figure 2.
PURE700 and PURE1400
Flow Salinity
Sensor
Ribb
on
Ca
ble
To
B
a
c
k
P
C
B
Front PCB
Reverse Side
Test Points
A to K
Stripe
Flow
Sensor
Test Points
Common
R
S
Test
Switches
Aux Board
Stripe
From Front
PCB
T
rans
fo
rm
e
r
R
ibbon
1
8
Test Points
1-8
Back
PCB
A
B
Black / White
Green
DC Cord
22 - 30 VDC
Ca
b
le
A
B
H
ORP
24 VAC
Use Copper Conductors Only – Rated for 90°C Minimum
Transformer
Factory Wired for
230 VAC
Re-wired for
115 VAC
Wire Nut Connections
Load 1
to Blk
Load 2
to Blk/Yel
Blk/Red to Blk/Wht
Wire Nut Connections
Load 1
to Blk/Wht and Blk/Yel
Load 2
to Blk/Red and Blk
RED BLK YEL GRN
AquaLink RS