Page 32
Problem
Possible Cause
Corrective Action
“Service” Indicator On.
Low salt level in pool water.
Test salinity. Add salt as described on pages 18
through 20.
Cell requires cleaning.
Refer to Maintenance Procedure for acid wash
cleaning. See pages 27 and 28.
Cell not working properly after cleaning
Contact your authorized service representative.
DC power cord not properly connected to the cell.
Check connection. Check for dirt or corrosion
around DC cord contacts at Cell. Check Cell studs
for same.
Flow/Temp/Salinity Sensor not plugged in.
Plug Flow/Temp/Salinity Sensor into connector on
control center printed circuit board. (Cycle Power).
Water temperature too low
Winterize your pool. See page 29.
All the above have been checked and indicator light is
still on.
Contact your authorized service representative.
Problem
Possible Cause
Corrective Action
Salt Level Too Low.
Not enough salt added on start up.
Add salt to pool, 3.0 gpl to 3.5 gpl.
See pages 18 through 20.
Heavy Rainfall.
Add salt to pool, 3.0 gpl to 3.5 gpl.
See pages 18 through 20.
Leak in pool.
Repair pool.
Dirty Flow/Temp/Salinity Sensor contacts
or faulty Flow Sensor.
Remove and clean Flow/Temp/Salinity Sensor
contacts. Check Flow/Temp/Salinity Sensor cable
for damage. See page 28. Verify salinity with Myron
“L” meter calibrated for NaCl, titration test units, or
other salt meters. Please be aware that salt test
strips have a large variance in readings
(400 - 800 ppm).