Figure 14.
Wiring AquaPure Power to an AquaLink RS Power Center
Filter Pump Relay
Aux. 3 Relay
Load
2
Line
2
Load
1
Line
1
To AquaPure PCB
(230 VAC)
To Breaker
Panel
To Filter Pump
230 VAC
AquaLink RS Power Center
NOTE
AquaPure Chlorine Generator will communicate with AquaLink RS using fi rmware versions JJ or
later
. When
the AquaPure is controlled by the optional Jandy AquaLink RS control system, the % output and hours must
be adjusted from the AquaLink RS control panel. However,
BOOST
is functional from the AquaPure.
3.6.1 Wiring to a Jandy AquaLink RS
In the AquaLink RS Power Center, wire the AquaPure power
directly
to the LOAD SIDE of the Filter Pump
relay (see Figure 14).
The Jandy AquaLink RS and AquaPure use a four (4) wire connection to communicate and can be wired
up to 500 feet apart. Any outdoor rated four (4) conductor cable can be used. Locate the appropriate screw
terminals on the circuit board according to Figure 15. Wire the master AquaPure from the red 4-pin terminal
bar to the AquaLink RS red 4-pin terminal bar (see Figure 15).
NOTE
The screw terminals are removable to aid in installation.
IMPORTANT
Attach the master AquaPure wires to the like-numbered screw terminals on both the AquaPure and
AquaLink RS as shown in Figure 15.
Figure 15.
Wiring an AquaPure to an AquaLink RS Control System Network
Jandy
Power Center
Front PCB
Reverse Side
Test Points
A to K
Flow
Sensor
R
S
Test
Switches
Aux Board
H
ORP
24 VAC
Red BLK YEL GRN
AquaLink RS
or
OPTIONAL
4 3 2 1
RED
BLK
YEL
GRN
RED BLK YEL GRN
AquaLink RS
AquaPure
(Master)
Red, 4-Pin
Terminal Bar
Summary of Contents for AquaPure Pure700