Page 4
Section 1. Safety Information
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:
WARNING
To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times.
WARNING
To reduce the risk of electric shock, fi re or injury, service should only be attempted by a qualifi ed Pool
Service Professional.
SAVE THESE INSTRUCTIONS
WARNING
When mixing acid with water,
ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID.
WARNING
Do not operate electrolytic cell without proper fl ow or water circulation. A buildup of fl ammable gases
would result in hazardous conditions.
WARNING
Installation must be done in accordance with the National Electric Code (NEC, NFPA-70) and/or any
other applicable local and national installation codes.
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH
. Connect only to a circuit
that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the
installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate
in this manner, there is ground current fl owing, indicating the possibility of an electric shock. Do not
use this unit. Disconnect this unit and contact a qualifi ed service representative before using.
A green colored terminal (or a wire connector marked “G”, “GR”, “Ground” or “Grounding”) is provided
within the terminal compartment. To reduce risk of electric shock, connect this terminal or connector
to the grounding terminal of your electric service or supply panel with a conductor equivalent in size
to the circuit conductors supplying this equipment.
Power supply must be interconnected with Pool Pump motor power source. This insures the
clorinator and pool pump will turn on and off together.
Use of chemicals other than those recommended may be hazardous. Follow the Chemical
Manufacturers Instructions.
It is recommended that the water Flow/Temp/Salinity Sensor is installed in the same piping as the
electrolytic cell, without any valves or diverters between them. (See page 5 Figure 1).
The Flow/Temp/Salinity Sensor must be mounted as in page 13 Figure 11.
Summary of Contents for AquaPure Pure700
Page 2: ......