Shock Arrestor Inspection/Replacement

(

Iceberg

 

POU Water Cooler

)

MAINTENANCE
Please note that only properly trained personnel may perform service and maintenance.

·

Ensure that the system is disconnected from the mains power supply, cooled and system drained of water 
prior to performing maintenance or repairs. 

·

Check the Shock Arrestor Pre-Charge annually (minimum) to verify that the internal pressure is within 
20% of the values indicated on the label (50 psi / 3.45 Bar if not otherwise stated).

·

In order to maintain the external surface of the expansion tank, periodical cleaning shall be performed, only 
using water and soap.

·

The Shock Arrestor is subjected to changes in system pressures, and may deteriorate over time; in the event 
that the Shock Arrestor no longer works, it should be replaced.

Note: To ensure the proper functioning of the system, the Shock Arrestor must be replaced in the event of 
excessive deterioration or every 5 years from installation date.

·

Use only Crystal Mountain original replacement parts.

CRYSTAL MOUNTAIN shall not be responsible for any damage to things, property and / or injuries to 
persons due to not observing all the above instructions and, particularly, operation and maintenance of 
the tank itself and / or the connected system.

YEARLY MAINTENANCE

Ensure that the system power is off and disconnected, and system not pressurized (Valve Open).

1.  Disconnect  power  supply  cord  (Figure  1),  turn  off  water  supply  valve  and  open  the  faucet  to  release  the 

water pressure (Figure 2 and Figure 3).

2. Disconnect the 2 connectors on top of the cooler (Figure 4), remove the screws from the front/back of the 

top cover (Figure 5 and Figure 6).

Figure

 

1

Figure

 

2

Figure

 

3

Open
faucet

Figure

 

4

Figure

 

5

Figure

 

6