Dimmer Operation
15
Revision 1.0 - 7-May-02
HUB24 Series Dimmer
Operating Manual
4.2.22
Error Log (5-4)
Menu
5 Diagnostics
5-4 Error Log
When an event occurs that generates an error or warning, a message is immediately
displayed on the LCD and an entry is placed in the error log.
Neutral Earth Warnings – see section 5.1.4.
Fan Activated Warning – see section 5.1.3.
Software Exception Error – see section 5.3.
The error log will hold up to 15 entries, if an 16th error occurs the oldest entry is
discarded to make room for the new entry. The error log can be viewed on the
display, the most recent entry will be at the bottom of the list.
•
Select “5-4 Error Log” to display a list of the entries in the error log.
•
Turn the encoder wheel to highlight one of the log entries.
•
Press SELECT to view more details of the log entry.
•
Press CANCEL to return to the error log list.
4.2.23
Clear Error Log (5-5)
Menu
5 Diagnostics
5-5 Clear Error Log
The error log can be cleared, with all the errors and warnings being removed.
•
Select “5-5 Clear Error Log” on the menu.
•
Press CONFIRM to clear the error log.
4.2.24
Control Source (5-6)
Menu
5 Diagnostics
5-6 Control Source
The control of each dimmer output can come from several sources:
- Test
- Playback a snapshot
- Playback a chase
- DMX
Test overrides the incoming DMX signal. Playback can be configured to override the
DMX signal or to merge the two (see section 4.2.14).
•
Select “5-6 Control Source” to display a list showing what source has been
assigned control of each dimmer output.
•
Turn the encoder wheel to scroll through the list.
Note: When in HTP playback mode, the list does not show when a DMX level is
higher than the assigned snapshot or chase.
To restore all dimmer outputs to DMX control, select “3-3 Clear Test” and
select “7-3 Clear Playback” with “7-3-1 All”.