SP-20000M-PMCL / SP-20000C-PMCL
- 14 -
Note
1.
In this table, all Tap Geometry items are not described. For instance, 1X2–1Y and 1X4–1Y show only
10-bit. In case of 8-bit, upper 2 bits (D8 and D9) are not used.
2. Please check whether the frame grabber complies with those formats if you use 80-bit (8Tap/10-bit)
camera configuration.
3. If you use 80-bit (8Tap/10-bit) camera configuration, DVAL and Exposure Active (JAI custom) are
not output through the Camera Link interface. FVAL is only output via Digital I/O-1 connector.
5.2.2 Camera Link Pixel clock
The SP-20000M-PMCL and SP-20000C-PMCL use the Camera Link pixel clock of 80 MHz as the
default setting. It can be changed.
Table – 5 Camera Link pixel clock
Camera Link
Pixel Clock
Tap
Geometry
Camera Link
Configuration
Note
80 MHz
1X8-1Y
80-bit, Full
Defaut setting
1X4-1Y
Medium
1X2-1Y
Base
60 MHz
1X8-1Y
80-bit, Full
1X4-1Y
Medium
1X2-1Y
Base
[Note]
If the Camera Link pixel clock is changed, the output is immediately changed but it may
take a few seconds for the output signal to be stable.
Base
Medium
Full
80bit
2Tap / 10bit
4Tap / 10bit
8 Tap / 8bit
8 Tap / 10bit
1X2 - 1Y
1X4 - 1Y
1x8 - 1Y
1X8 - 1Y
Port G0
TxIN 0
―
―
Tap 7 D0
Tap 7 D2
Port G1
TxIN 1
―
―
Tap 7 D1
Tap 7 D3
Port G2
TxIN 2
―
―
Tap 7 D2
Tap 7 D4
Port G3
TxIN 3
―
―
Tap 7 D3
Tap 7 D5
Port G4
TxIN 4
―
―
Tap 7 D4
Tap 7 D6
Port G5
TxIN 6
―
―
Tap 7 D5
Tap 7 D7
Port G6
TxIN 27
―
―
Tap 7 D6
Tap 7 D8
Port G7
TxIN 5
―
―
Tap 7 D7
Tap 7 D9
Port H0
TxIN 7
―
―
Tap 8 D0
Tap 8 D2
Port H1
TxIN 8
―
―
Tap 8 D1
Tap 8 D3
Port H2
TxIN 9
―
―
Tap 8 D2
Tap 8 D4
Port H3
TxIN 12
―
―
Tap 8 D3
Tap 8 D5
Port H4
TxIN 13
―
―
Tap 8 D4
Tap 8 D6
Port H5
TxIN 14
―
―
Tap 8 D5
Tap 8 D7
Port H6
TxIN 10
―
―
Tap 8 D6
Tap 8 D8
Port H7
TxIN 11
―
―
Tap 8 D7
Tap 8 D9
(Port I5)
TxIN 15
―
―
―
Tap 3 D1
(Port I6)
TxIN 18
―
―
―
Tap 4 D0
(Port I7)
TxIN 19
―
―
―
Tap 4 D1
(Port K0)
TxIN 20
―
―
―
Tap 5 D0
(Port K1)
TxIN 21
―
―
―
Tap 5 D1
(Port K2)
TxIN 22
―
―
―
Tap 6 D0
(Port K3)
TxIN 16
―
―
―
Tap 6 D1
(Port K4)
TxIN 17
―
―
―
Tap 7 D0
-
TxIN 24
―
―
LVAL
LVAL
(Port K5)
TxIN 25
―
―
FVAL
Tap 7 D1
(Port K6)
TxIN 26
―
―
DVAL
Tap 8 D0
(Port K7)
TxIN 23
―
―
Exposure Active
Tap 8 D1
D
i
g
i
t
a
l
I
/
O
-
2
(
2
/
2
)
SP-20000M/C-PMCL
Port
Camera Link Configuration
Camera Link port/bit