SP-20000M-PMCL / SP-20000C-PMCL
- 42 -
Table 23
Frame rate interval setting range (typical value) in Continuous Trigger mode
Camera Settings
ART Command value (limited standard value)
Tap
Geometry
Camera
Link
Pixel Clock
Binning
Vertical
Height
Min.
Max.
Setting
value
Actual
operating
time/Actual
operating
interval
Setting
value
Actual
operating
time/Actual
operating
interval
1X8-1Y
80 MHz
1 (Off)
3840
31995
31.996 ms /
8 000 000
8 sec /
0.125 Hz
31.254 Hz
2 (On)
1920
31978
31.979 ms /
31.271 Hz
60 MHz
1 (Off)
3840
42965
42.966 ms /
23.274 Hz
2 (On)
1920
42942
42.942 ms /
23.287 Hz
1X4-1Y
80 MHz
1 (Off)
3840
63990
63.992 ms /
15.627 Hz
2 (On)
1920
63957
63.959 ms /
15.635 Hz
60 MHz
1 (Off)
3840
85929
11.637 Hz
85.933 ms
2 (On)
1920
85885
85.889 ms /
11.643 Hz
1X2-1Y
80 MHz
1 (Off)
3840
127981
127.982 ms /
7.8136 Hz
2 (On)
1920
127915
127.916 ms /
7.8176 Hz
60 MHz
1 (Off)
3840
171860
171.860 ms /
5.8187 Hz
2 (On)
1920
171772
171.771 ms /
5.8217 Hz
Note:]
1. The above reference value is the setting range to which frame interval is automatically changed if Height
is set at Height Max. In vertical ROI operation, if Height is set at less than Height Max, the minimum
setting value will be smaller. Use Table 17 to calculate the minimum Frame Rate interval in vertical ROI
operation.
2. In the SP-20000-PMCL, the frame rate in 1X8-1Y and Full Line setting can be set at a maximum of 31.250
fps. However, it is only guaranteed up to 30 fps in terms of performance.
3. In the SP-20000M-PMCL and SP-20000C-PMCL, the frame rate has maximum 1 line longer or shorter
depending on the exposure time. This happens, when the exposure executes for the next frame while
the previous video is reading out, the increment or of 1 μs for the exposure time is completed at the
exposure completion side. Refer to 7.2.3.
^