Configuring the Camera
55
RM/TM-2040GE Series
Category / Feature
Read/
Write Value Range
Default Value
Visibility
Level
AcquisitionRecordingWrapAround
RW
True
False
False
Expert
BlockBufferCount
RO
Expert
BlockBufferCurrentIndex
WO
0 to BlockBufferCount-
1
Expert
ExposureMode
RW
Off
ContinuousProgramma
ble AsyncNoShutter
PulseWidthControl
FixedExposurePIV
PWC_PIV
AsyncProgrammable
Off
Beginner
AsyncProgrammable
RW
0-2079
Factory Set
Beginner
ContinousProgrammable
RW
ScanMode Limited:
A: 0-1300
B: 0 - 700
C: 0 - 500
D: 0 – 350
U: 0 - 1300
T: 0 - 700
Factory Set
Beginner
TriggerPolarity
RW
ActiveLow
ActiveHigh
ActiveLow
Beginner
AnalogControls
GainSelector
RW
All
Tap2
All
Beginner
GainRaw
RW
0 - 4095
Factory Set
Beginner
GainAutoBalance
RW
Off
Once
Off
Beginner
BlackLevelSelector
RW
All
Tap2
All
Expert
BlackLevelRaw
RW
0 - 4095
Factory Set
Expert
BlackLevelAutoBalance
RW
Off
Continuous
Continuous
Expert
CountersAndTimersControls
TimerSelector
RW
Timer1
Timer2
Timer3
Timer4
Timer1
Beginner
TimerDelayRaw
RW
1-65535
1024
Beginner
TimerDurationRaw
RW
1-65535
4096
Beginner
TimerGranularityFactor
RW
1-65535
0
Beginner