Configuring the Camera
47
RM/TM-2040GE Series
PLC_ctrl0
X
X
X
X
X
X
PLC_ctrl2
X
X
X
X
PLC_ctrl3
X
X
X
PLC_Q2
X
X
X
X
PLC_Q3
X
X
X
X
PLC_Q6
X
X
X
X
PLC_Q7
X
X
X
X
Counter1Gt
X
X
X
Counter1Eq
X
X
X
Timer1Out
X
X
X
X(D)
Timer2Out
X
X
X
X(D)
Timer3Out
X
X
X(D)
X
Timer4Out
X
X
X
5.9.2
ControlBits
There are 3 Control Bits: PLC_ctrl0, PLC_ctrl2, and PLC_ctrl3. Note that PLC_ctrl1 is not available. The control
bits can be used as software triggers by toggling between two states: True and False. True sets the signal High,
while False sets the signal to Low.
When a bit is toggled on the host software, a Write Register command is sent to the camera. The arrival time
of the packet depends on current network traffic therefore is varied. These are recommended for testing
purposes. For more precise trigger usage please use an external input trigger signal thru the 12-Pin connector.
For a constant periodic trigger signal please use the Pulse Generators (Timers).
Figure 31.
ControlBits