User Manual (Ver. 1.0) - Setting List
GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
- 134 -
Acquisition Control
Item
Setting Range
Default Value
Description
TriggerMode
0:Off
1:On
0:Off
Select the trigger mode.
TriggerSoftware
-
-
Execute a software trigger.
TriggerSource
-
24: Line5 Opt In
Select the trigger signal source.
7-10: PulseGenerator0-3
11-14: UserOutput0 -3
15-18: Action0-3
19:Software
24: Line5 Opt In
36: Nand0 Out
37: Nand1 Out
TriggerActivation
1:Rising Edge
2:Falling Edge
3:Level High
4:Level Low
1:Rising Edge
Select the polarity of the trigger signal (i.e., location of signal at
which trigger is applied).
TriggerOverlap
0: Off (fixed)
1: ReadOut
-
Select the trigger overlap operation.
TriggerSelector(AcquisitionStart/AcquisitionEnd/AcquisitionTransferStart)
= 0:Off (Fixed)
TriggerSelector(FrameStart) = 1: ReadOut
TriggerDelay
0 - 500000
0
Set the time of exposure start from trigger input. (unit: μs)
ExposureMode
Related Topic:
0: Off
1: Timed
2: TriggerWidth
1: Timed
Select the exposure mode.
ExposureTime (us)
Related Topic:
-
-
Set the exposure time (us).
Note:
The actual exposure time will consist of the image sensor’s
offset duration (2.45us) added to the ExposureTime setting.
Min
: 1
Max
: (1/AcqusitionFrameRateMax) - Next trigger prohibited time.
Default
:
GOX-5105MC-5GE: 9853
GOX-8105MC-5GE: 15615
GOX-12405MC-5GE: 23745
GOX-16205MC-5GE: 30896
GOX-20405MC-5GE: 38470
GOX-24505MC-5GE: 46356