User Manual (Ver. 1.0) - Main Functions
GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
- 74 -
GOX-5105M-5GE, GOX-5105C-5GE
Exposure Mode = Timed (Frame Start Trigger On, RCT Mode)
Pixel Format
Frame Period [A] (usec)
Period From Trigger Start
Edge to Exposure Start [B]
(usec)
Data Invalid Period [C]
(usec)
Full (Max Frame Rate), Exposure Time Minimum
Mono8
103093
1819.4
92269
Mono10, Mono12
103093
1872.6
83257
Mono10Packed,
Mono12Packed
103093
1846.0
87763
BayerRG8
103093
1819.4
92269
BayerRG10, BayerRG12
103093
1872.6
83257
BayerRG10Packed,
BayerRG12Packed
103093
1846.0
87763
RGB8
103093
1920.9
75032
RGB10V1Packed, RGB10p32
103093
1972.5
66276
Binning Horizontal (Max Frame Rate), Exposure Time Minimum
Mono8
103093
1818.1
92471
Mono10, Mono12
103093
1819.4
92263
Mono10Packed,
Mono12Packed
103093
1818.1
92471
Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
103093
1818.1
92472
Mono10, Mono12
103093
1819.4
92265
Mono10Packed,
Mono12Packed
103093
1818.1
92472
Binning Horizontal & Binning Vertical (Max Frame Rate), Exposure Time Minimum
Mono8
103093
1818.1
92467
Mono10, Mono12
103093
1818.1
92466
Mono10Packed,
Mono12Packed
103093
1818.1
92467