User Manual (Ver. 1.0) - Setting List
GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
- 152 -
CounterAndTimerControl
Configure counter settings.
Note:
This camera only supports the counter functions.
Related Topic:
Counter and Timer Control Function
Counter and Timer Control Item
Setting
Range
Default
Value
Description
CounterSelector
0: Counter0
1: Counter1
2: Counter2
3: Counter3
0: Counter0
Select the counter.
CounterEventSource
-
0: Off
Assign the Counter Event signal for which you want to read the count
value to a dedicated counter, and read the value.
0: Off
1: FrameTrigger (Counter0 only)
2: Exposure Start (Counter1 only)
3: Sensor Readout (Counter2 only)
4: FrameTransferEnd (Counter3 only)
CounterEventActivation
1:Rising
Edge
2:Falling
Edge
-
Set the count timing. The setting value is fixed with the following data.
Default
:
CounterSelector=0, 1, 2: Rising Edge
CounterSelector=3: Falling Edge
CounterReset
-
-
Reset the counter.
CounterValue
0 ~ 32bit
max
0
Display the count value.
CounterStatus
-
0:
CounterIdle
Display the counter status.
0: CounterIdle
1: CounterTriggerWait
2: CounterActive
3: CounterCompleted
4: CounterOverflow - Count value exceeded the maximum value