— 54 —
GO-5100M-PGE / GO-5100C-PGE
Item
Setting range
Default value
Description
Shading Detect Result
—
—
Display the shading correction results.
q) JAI Custom Control Sensor
MultiROI
Configure settings for JAI sensor multi
ROI.
Sensor Multi Roi Enable
True, False
False
Enable/disable sensor Multi Roi.
Sensor Multi Roi Index
Index 1 to 8
Index 1
Select the index for the sensor Multi Roi
mode.
Sensor Multi Roi Width
96 to 2464
2464
Set the width for the selected sensor Multi
Roi index.
Sensor Multi Roi Height
2 to 2056
2056
Set the height for the selected sensor
Multi Roi index.
Sensor Multi Roi Offset X
0 to 2448
0
Set the horizontal offset for the selected
sensor Multi Roi index.
Sensor Multi Roi Offset Y
0 to 2054
0
Set the vertical offset for the selected
sensor Multi Roi index.
Sensor Multi Roi Horizontal
Enable
Off, On
Off
Enable/disable Width/Offset X for the
selected sensor Multi Roi index.
Sensor Multi Roi Vertical
Enable
Off, On
Off
Enable/disable Width/Offset Y for the
selected sensor Multi Roi index.
r) CounterAndTimer Control
Configure counter settings. (This camera
only supports counter functions.)
Counter 0 to 2
Counter 0 to 2
—
Select the counter.
Counter 0 to 2 Event
Source
Off,
Frame Trigger,
Frame Start,
Exposure Start,
Exposure Transfer End
Off
Select the counter event signal for which
to read the count value.
Counter 0 to 2 Event
Activation
Rising Edge
Falling Edge
—
Display the timing at which to count.
Counter 0 to 2 Reset
—
—
Reset the counter.
Counter 0 to 2 Refresh
—
—
Update the count value.
Counter 0 to 2 Value
—
0
Display the count value.
Counter 0 to 2 Status
Counter Active
Counter Active
Display the counter status.
s) JAI Custom control features
Misc.
Configure settings for other JAI functions.
Video Process Bypass
Mode
On, Off
Off
Enable / disable video process bypass
mode.
Trigger Option
Off
Off
—
AWB Area Selector
(GO-5100C-PGE only)
Low Right
Low Mid-Right
Low Mid-Left
Low Left
Mid-Low Right
Mid-Low Mid-Right
Mid-Low Mid-Left
Mid-Low Left
Mid-High Right
Mid-High Mid-Right
Mid-High Mid-Left
Mid-High Left
High Right
High Mid-Right
High Mid-Left
High Left
Low Right
Select the area for which to configure
[AWB Area Enable].
AWB Area Enable
Off, On
Off
Enable/disable the photometry area
selected in [AWB Area Selector].
AWB Area Enable All
Off, On
Off
On: Operate AWB with all areas
designated as photometry areas,
regardless of the individual enabled/
disabled states configured in [AWB
Area Selector].
Off: Operate AWB according to the
individual enabled/disabled
photometry area states configured in
[AWB Area Selector].
AWB Control Speed
1 (slow) to 8 (fast)
4
Set the AWB control speed. (8 is the
fastest.)