— 29 —
GO-5100M-PGE / GO-5100C-PGE
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning range
Shortest period
8-bit (at 14 μs)
10-bit packed (at 27 μs)
10-bit (at 27 μs)
Full
44.05 ms
66.08 ms
88.10 ms
ROI 2/3 (Height = 1370)
19.56 ms
37.14 ms
39.12 ms
ROI 1/2 (Height = 1028)
14.32 ms
28.13 ms
28.13 ms
ROI 1/4 (Height = 514)
7.43 ms
14.59 ms
14.59 ms
ROI 1/8 (Height = 257)
3.98 ms
7.82 ms
7.82 ms
Binning Vertical 2*
22.03 ms
33.04 ms
44.05 ms
The values in parentheses indicate exposure time.
* GO-5100M-PGE only
The shortest periods of trigger in the table above are values for when the trigger overlap is set to
“Readout.” When the trigger overlap is set to “Off,” the exposure time will be added to the periods.
■
When [Exposure Mode] is [Timed]
Example: When [Trigger Source] is set to [Line 5 - Optical In 1] and [OptIn Filter Selector] is set to
[10 µs]
•
Trigger overlap: Off
FVAL
Readout duration
Next trigger disabled
Next trigger
input enabled
Sensor
Exposure
Trigger
(= Height x Line Period)
EEN
t2
t3
t4
t1
t1
t2
t3
t4
8-bit
10 µs (minimum)
52 µs
464 µs
16.0 ms
10-bit packed
91 µs
903 µs
10.9 ms
10-bit
32.9 ms