— 9 —
GO-5100M-PGE / GO-5100C-PGE
2
RJ-45 connector
Connect a Gigabit Ethernet compatible LAN cable (Category 5e or higher, Category 6
recommended) here.
1
2
3
4
5
6
7
8
Pin No.
Input/
output
Description
1
In/Out
MX1+ (DA+)
2
In/Out
MX1– (DA–)
3
In/Out
MX2+ (DB+)
4
In/Out
MX3+ (DC+)
5
In/Out
MX3– (DC–)
6
In/Out
MX2– (DB–)
7
In/Out
MX4+ (DD+)
8
In/Out
MX4– (DD–)
3
Power/trigger LED
Indicates the power and trigger input status.
4
ACT LED
Indicates the GigE network status.
5
LINK LED
Indicates whether the GigE network connection is 1000BASE-T or 100BASE-TX.
The specifications described in this manual, such as those for frame rate and trigger frequency, cannot be
met when using a 100BASE-TX connection.
LED status and camera status
LED
Light
Status
Power / trigger LED
Lit amber
Camera initializing.
Lit green
Camera in operation.
Blinking green
During operation in trigger mode, trigger signals are being
input.
The blinking interval is not related to the actual input interval
of the external trigger.
ACT LED
Lit amber
GigE network communication not established.
Blinking amber
GigE network communication in progress.
LINK LED
Lit green
100BASE-TX connection established.
Blinking green
1000BASE-T connection established.