— 48 —
GO-5100M-PGE / GO-5100C-PGE
Item
Setting range
Default value
Description
d) Event Control
Configure event control settings.
Event Selector
Line1 - TTL Out,
Line4 - TTL In,
Line7 - CC1,
NAND Gate 0 In 1,
NAND Gate 0 In 2,
NAND Gate 1 In 1,
NAND Gate 1 In 2
Line7 - CC1
Select the event for which to send
notifications.
Event Notification
Off, On
Off
Select whether to output event messages.
e) Analog Control
Configure analog control settings.
Gain Selector
GO-5100M-PGE:
Analog All
GO-5100C-PGE:
Analog All,
Digital Red All,
Digital Blue All
Analog All
Select the gain to configure.
Gain
Analog All: 1 to 16
Digital Red All and Digital
Blue All: 0.4467 to
5.6235
Master gain: 1
R, B: 1
Set the gain value for the gain setting
selected in [Gain Selector].
Black Level Selector
GO-5100M-PGE:
Digital All
GO-5100C-PGE:
Digital All,
Digital Red,
Digital Blue
Digital All
Select the black level to configure.
Black Level
–133 to 255
0
Set the black level value.
Gain Auto
Off, Continuous
Off
Enable/disable gain auto adjustment.
Balance White Auto
(GO-5100C-PGE only)
Off,
Once,
Continuous,
Preset 4600K,
Preset 5600K,
Preset 6500K
Off
Enable/disable auto white balance.
Gamma
0.45, 0.60, 1.0
1.0
Set the gamma value.
JAI LUT Mode
Off, Gamma, LUT
Off
Select the JAI LUT mode.
f) LUT Control
Configure LUT settings.
LUT Selector
GO-5100M-PGE:
Mono
GO-5100C-PGE:
Red,
Green,
Blue
GO-5100M-PGE:
Mono
GO-5100C-PGE:
Green
Select the LUT channel to control.
LUT Index
0 to 255
0
Set the LUT index table number.
LUT Value
0 to 4095
0
Set the LUT value.
g) Sequencer Control
Configure sequencer settings.
Sequencer Mode
On, Off
Off
Enable/disable [Sequencer Mode].
Sequencer Mode Select
Trigger Sequencer,
Command Sequencer
Trigger
Sequencer
Select the sequencer mode.
Sequencer Configuration Mode On, Off
Off
Select [On] to change the settings within
the index.
Sequencer Set Selector
1 to 128
1
Select the [Trigger Sequencer] mode and
[Command Sequencer] mode index.
Sequencer Frame Number
1 to 255
1
Set the number of frames to display for
the selected Sequencer Index. (Enabled
only for Trigger Sequencer.)
Sequencer Set Next
1 to 128
1
Set the next index to be displayed for the
selected Sequencer Index. (Enabled only
for Trigger Sequencer.)
Sequencer Width
96 to 2464
2464
Set the width of the selected Sequencer
Index.
Sequencer Height
2 to 2056
2056
Set the height of the selected Sequencer
Index.
Sequencer Offset X
0 to 2448
0
Set the horizontal offset value for the
selected Sequencer Index.
Sequencer Offset Y
0 to 2054
0
Set the vertical offset value for the
selected Sequencer Index.