GO-2400M-PMCL-1 | GO-2400C-PMCL-1 | User Manual (Ver. 1.0)
Main Functions
- 50 -
Tap
Geometry
CL Pixel
Clock (MHz)
Period From
Trigger start
edge to
Exposure
start [A]
(usec)
Period from
Exposure
endTo FVAL
start [B]
(usec)
Period FVAL
end to next
trigger start
[C] (usec)
Max
Exposure
[msec]
Min Exposure
[usec]
Horizontal
ROI
ALL
↓
↓
↓
Framerate -
13/H Freq
3/H Freq
+ 22×0.013 +
13.7
1X2 - 1Y (Full)
37.125
80
884
≧
89
7999.658
92.7
74.25
40
452
≧
37
7999.829
53.7
84.85
38
428
≧
34
7999.838
51.7
1X8 - 1Y (Full)
37.125
60
654
≧
65
7999.748
72.7
74.25
27
300
≧
11
7999.886
40.7
84.85
24
263
≧
24
7999.900
37.7
1X4 - 1Y (Full)
37.125
41
454
≧
37
7999.828
53.7
74.25
21
228
≧
18
7999.914
33.7
84.85
20
214
≧
17
7999.919
32.7
1X3 - 1Y (Full)
37.125
22
232
≧
17
7999.912
34.7
74.25_8
16
168
≧
13
7999.937
28.7
74.25_10
20
214
≧
19
7999.919
32.7
84.85_8
15
167
≧
2.1
7999.937
28.7
84.85_10
20
214
≧
19
7999.919
32.7
Smallest input pulse width of trigger signal: 10 μS or more