GO-2400M-PMCL-1 | GO-2400C-PMCL-1 | User Manual (Ver. 1.0)
Short ASCII Command List
- 112 -
Name
Access
Short
ASCII
Values
Default
AWBChannelAreaAll
R/W
AWBA
0: OFF
1: ON
Color model only.
1
AWBA=[Param.]<CR><LF>
AWBA?<CR><LF>
On
: Specify all photometry areas
for AWB, regardless of the
enabled/disabled statuses
configured individually for each
photometry area with [AWB Area
Selector].
Off
: Specify areas for AWB based
on the enabled/disabled statuses
configured individually for each
photometry area with [AWB Area
Selector]
AWBChannelArea
R/W
AWBLR
AWBLMR
AWBLML
AWBLL
AWBMLR
AWBMLMR
AWBMLML
ALMLL
AWBMHR
AWBMHMR
AWBMHML
ALMHL
AWBHR
AWBHMR
AWBHML
AWBHL
0: Off
1: On
Default: 0
AWB***=[Param.]<CR><LF>
AWB***?<CR><LF>
Enable/disable the specified photometry area. (Color model
only)
16 Photometry Areas and Short ASCII Commands.
AWBHL
(High Left)
AWBHML
(Hight Mid-
Left)
AWBHMR
(High Mid-
Right)
AWBHR
(High Right)
AWBLMHL
(Mid-High
Left)
AWBMHML
(Mid-Hight
Mid-Left)
AWBMHMR
(Mid-High
Mid-Right)
AWBMHR
(Mid-High
Right)
AWBLMLL
(Mid-Low Left)
AWBMLML
(Mid-Low Mid-
Left)
AWBMLMR
(Mid-Low Mid-
Right)
AWBMLR
(Mid-Low
Right)
AWBLL
(Low Left)
AWBLML
(Low Mid-
Left)
AWBLMR
(Low Mid-
Right)
AWBLR
(Low Right)
CurrentAreaNoRequest
R/O
EA
0: Factory area
1: User 1 area
2: User 2 area
3: User 3 area
0
EA?<CR><LF>
Display the currently configured
Use Set Selector status. (Start up
with the state saved to this area.)
The camera returns the latest used
DATA AREA.