Trigger Overlap: Readout
Tap Geometry
CL Pixel Clock
(MHz)
Period From
Trigger start
edge to
Exposure start
[A](μsec)
Min Exposure
(μsec)
Period from
Exposure end to
FVAL start [B]
(μsec)
Minimum
Trigger Period
[C](μsec)
1X2 - 1Y (Full)
37.125
80
79
884
33021
74.25
40
40
452
16511
84.85
38
38
428
15630
1X3 - 1Y (Full)
37.125
60
59
654
24395
74.25
27
27
300
11047
84.85
24
24
263
9711
1X4 - 1Y (Full)
37.125
41
40
454
16646
74.25
21
20
228
8323
84.85
20
19
214
7815
1X8 - 1Y (Full)
37.125
22
21
232
8457
74.25_8
16
15
168
7815
74.25_10
20
19
214
6094
84.85_8
15
15
167
6038
84.85_10
20
19
214
7814