![JAI GO-2400M-PMCL-1 User Manual Download Page 116](http://html1.mh-extra.com/html/jai/go-2400m-pmcl-1/go-2400m-pmcl-1_user-manual_3274882116.webp)
GO-2400M-PMCL-1 | GO-2400C-PMCL-1 | User Manual (Ver. 1.0)
Short ASCII Command List
- 116 -
Name
Access
Short
ASCII
Values
Default
GpioNand1
InputInvert1
R/W
ND1INV1
0: Non-Inv
1: Inv
0
ND1INV1=[Param.]<CR><LF>
ND1INV1?<CR><LF>
Not required. LineInverter_
Nand1In1 exists.
GpioNand0
InputInvert2
R/W
ND0INV2
0: Non-Inv
1: Inv
0
ND0INV2=[Param.]<CR><LF>
ND0INV2?<CR><LF>
Not required. LineInverter_
Nand1In1 exists.
GpioNand1
InputInvert2
R/W
ND1INV2
0: Non-Inv
1: Inv
0
ND1INV2=[Param.]<CR><LF>
ND1INV2?<CR><LF>
Not required. LineInverter_
Nand1In1 exists.
LUTSequenceR
R/W
LUTSR
0 ~ 4095
Color model only.
0
LUTSR =[Param.]<CR><LF>
LUTSR?<CR><LF>
When 256 commands are sent in
succession, the LUT curve is
updated (during WRITE) or the LUT
curve is loaded sequentially
(during READ). (Red signal)
LUTSequenceG
R/W
LUTSG
0 ~ 4095
Color model only.
0
LUTSG =[Param.]<CR><LF>
LUTSG?<CR><LF>
When 256 commands are sent in
succession, the LUT curve is
updated (during WRITE) or the LUT
curve is loaded sequentially
(during READ). (Green signal)
LUTSequenceB
R/W
LUTSB
0 ~ 4095
Color model only.
0
LUTSG =[Param.]<CR><LF>
LUTSG?<CR><LF>
When 256 commands are sent in
succession, the LUT curve is
updated (during WRITE) or the LUT
curve is loaded sequentially
(during READ). (Blue signal)
BlemishNum
R/O
BNUM
0 ~ 255
0
BNUM?<CR><LF> .
Display the number of correction
blemishes.
CameraLinkClock
Frequency
R/W
CLCF
0= 84.85MHz
1= 74.25MHz
2= 37.12MHz
1
CLCF =[Param.]<CR><LF>
CLCF?<CR><LF>
Set eh Camera Link clock.