GO-2400M-PMCL-1 | GO-2400C-PMCL-1 | User Manual (Ver. 1.0)
Short ASCII Command List
- 111 -
Name
Access
Short
ASCII
Values
Default
ALCChannelAreaAll
R/W
ALCA
0: OFF
1: ON
1
ALCA=[Param.]<CR><LF>
ALCA?<CR><LF>
On
: Specify all photometry areas
for ALC, regardless of the
enabled/disabled statuses
configured individually for each
photometry area with [ALC Area
Selector].
Off
: Specify areas for ALC based
on the enabled/disabled statuses
configured individually for each
photometry area with [ALC Area
Selector].
ALCChannelArea
R/W
ALCLR
ALCLMR
ALCLML
ALCLL
ALCMLR
ALCMLMR
ALCMLML
ALMLL
ALCMHR
ALCMHMR
ALCMHML
ALMHL
ALCHR
ALCHMR
ALCHML
ALCHL
0: Off
1: On
Default: 0
ALC***=[Param.]<CR><LF>
ALC***?<CR><LF>
Enable/disable the specified photometry area.
16 Photometry Areas and Short ASCII Commands.
ALCHL
(High Left)
ALCHML
(Hight Mid-
Left)
ALCHMR
(High Mid-
Right)
ALCHR
(High Right)
ALCMHL
(Mid-High
Left)
ALCMHML
(Mid-Hight
Mid-Left)
ALCMHMR
(Mid-High
Mid-Right)
ALCMHR
(Mid-High
Right)
ALCMLL
(Mid-Low Left)
ALCMLML
(Mid-Low Mid-
Left)
ALCMLMR
(Mid-Low Mid-
Right)
ALCMLR
(Mid-Low
Right)
ALCLL
(Low Left)
ALCLML
(Low Mid-
Left)
ALCLMR
(Low Mid-
Right)
ALCLR
(Low Right)
RequestBalanceWhite
AutoResult
R/O
AWRS
0=Complete.
1=Too Bright.
2=Too dark.
3=Timeout Error.
4=Busy.
5=Limit.
6= Trig is not set as
Normal.
0
AWRS?<CR><LF>
Display the AWB Once results.
Color model only.