background image

JADEVER SCALE 

SNUG III                                                                                                                               

1

 

 

 

Ⅰ.

Preparation before using 

1-1 Cautions before using 

The site for fixing the scale must be stable and even, and its level adjustment may be 

performed by referring to page 4 

Adjustment of leveler

 The ambient temperature must not exceed 0

40

, and the condition with too 

drastic temperature fluctuation should be avoided. 

 After starting, the scale must be energized for at least 10 min. before using. 

 The scale must not be used in a condition with strong wind, vibration, or 

electromagnetic interference (for example, near the outlet of cool air, in front of a fan, or 

near a heavy-duty machine). 

 Never impact or drop the scale, or press the scale with something whose weight 

exceeds the maximal capacity of the scale. 

 Never expose the scale to rains or wash the scale with water. 

 Be careful not to let cockroaches or other pest insects enter the scale. 

 Be sure to select the suitable transformer whose output is DC 9V / 400ma (please use a 

separate power socket and the transformer delivered by the scale manufacturer in order 

to avoid interference) 

 Change the batteries as soon as possible when battery symbol appears; if the scale 

uses batteries as its main power supply and the scale will be idle for a long term, the 

batteries must be removed to avoid the damage of scale due to the leakage of battery 

electrolyte. 

 Application of improper batteries or wrong connection may lead to the failure of system 

or other adverse effect.

 

1-2 Specification and characteristics of products 

Model 

SNUG III-150 

SNUG III-300 SNUG III-600 SNUG III-600  SNUG III-3000

Capacity (g) 

150 

300 

600 

1500 

3000 

Resolution (g) 

0.005/0.002 

0.01/0.005 0.01/0.02 0.05/0.02 0.1/0.05 

Display 

LCD and backlight sheet, 14mm(H)X7mm(W) weight--- 6 digitals 

Pan size 

(mm) 

125 stainless 

steel round pan 

146×125 stainless steel square pan 

Overall size 

245×175×147 

Power supply 

9V DC transformer 50/60Hz, or 2# dry battery*4 

 

Summary of Contents for SNUGIII Series

Page 1: ...2 Specificatin of counting function 3 3 Specification of percentage function 3 4 Setting of time and date 4 4 5 5 Setting of various parameters 4 1 Entry and parameter adjustment mode 4 2 Specificati...

Page 2: ...ects enter the scale Be sure to select the suitable transformer whose output is DC 9V 400ma please use a separate power socket and the transformer delivered by the scale manufacturer in order to avoid...

Page 3: ...sted of 5 components and they must be assembled together before being used 2 First assemble four sides of windshield A B by inserting A into B from top to bottom or from bottom to up 3 Place the assem...

Page 4: ...on specification of buttons and display window Button for Start Stop Button for zeroing It returns the weight to zero may return the value displayed on screen to zero position zeroing range is 2 of th...

Page 5: ...Press down button to shift the weighing units Caution the symbol of weighing unit will flash when the weight becomes unstable during the weighing 3 2 Specification of counting function 1 Under the wei...

Page 6: ...ntity place the article whose quantity is the same with the selected one on the scale pan and press down button to begin sampling when the sound bi is heard and SE is disappeared the sampling process...

Page 7: ...then press down button to select Internal option Procedure 3 After completing the modification of internal options press down button to exit in case the next option should be set press down button to...

Page 8: ...ed may be cancelled temporarily Press down button to select ON OFF and complete the setting Ozt TROY OUNCE ON in use or OFF not in use Dwt PENNY WEIGHT ON in use or OFF not in use MM JPN ON in use or...

Page 9: ...ime AU 60 Auto Stop 60 min later 2400 4800 Setting of RS 232 transmission function Note Selection of transmission speed 9600 d 0 No limitation of zero display d 1 In case the indication is below zero...

Page 10: ...ff Auto backlight off No backlight Backlight mode of display window Note there are three backlight modes that may increase effectively the convenience of application on Backlight keeps ON Pr co Signal...

Page 11: ...rocedure 1 Under Stop mode first hold down button then press down button once to energize the scale and then release button Count Procedure 2 Press down button to enter calibration mode CAL Procedure...

Page 12: ...cale and then release all pressed buttons L CAL Procedure 2 After clearing away the scale pan press down button to enter zero calibration On0 Procedure 3 After the sound bi is heard place the weight e...

Page 13: ...right of SNUG III pin 2 is for signal output and pin 5 is for grounding and other pins are in reserve BAUD RATE 2400 OR 4800 OR 9600 bps DATA BIT 8 PARITY BIT N NONE STOP BIT 1 CODE ASCII BIT FORMAT L...

Page 14: ...ial transmission speed should be set correspondingly USB peripheral devices should be used as follows 1 Connect this electronic scale to a computer with USB line and then start the electronic scale in...

Page 15: ...t Err5 The weight of an article exceeds the maximal capacity 9e Remove the over heavy article from the pan promptly and avoid the similar error from then to avoid the possible damage Err6 The weight f...

Page 16: ...we beg your pardon for this 1 You fail to show the warranty of products or the writing of the warranty is too illegible to be discerned 2 The damage of scale is due to the abnormal or incorrect appli...

Reviews: