background image

JADEVER SCALE 

SNUG III                                                                                                                               

9

 

 

 

 

 

 

d 4 

In case the indication is below 

zero, the value may be 
displayed only after at least 5 
resolutions are loaded. 

 

 

 

d 5 

In case the indication is below 

zero, the value may be 
displayed only after at least 6 
resolutions are loaded. 

 

FIL 1 

The application environment 

of the scale is excellent. 

FIL 2 

The application environment 

of the scale is good 

 

FIL 4 

The application environment 

of the scale is adequate 

 

Anti-vibration 

function 

Note: it may improve the 
weighing instability 
caused by environment 
and other interferences.

 

 

FIL 8 

The application environment 

of the scale is poor 

onoff 

Auto backlight 

 

off 

No backlight 

 

Backlight mode of 

display window 

Note: there are three 
backlight modes that may 
increase effectively the 
convenience of 
application.

 

 

on 

Backlight keeps ON 

Pr-co 

Signals transmit continuously. 

In case this option is 
selected, peripheral devices 
may only be set to “PC”. 

 

Setting of printing 

mode 

Note: the mode of signal 

transmission.

 

 

Pr-st 

Signals transmit automatically 

only when the weighing 
process becomes stabilized. 
In case this option is 
selected, all options for 
peripheral devices may be 
selected. 

PC 

Computers 

 

SH-24 

Common printers 

 

ZEBRA 

Option specially for Zebra 

printer 

 

Selection of 

peripheral devices 

Note: It may support the 
general requirement of 
peripheral devices. The 
model of built-in printer is 
also the common 
commercial mode.

 

 

BP-443 

Thermosensitive printer 

Summary of Contents for SNUGIII Series

Page 1: ...2 Specificatin of counting function 3 3 Specification of percentage function 3 4 Setting of time and date 4 4 5 5 Setting of various parameters 4 1 Entry and parameter adjustment mode 4 2 Specificati...

Page 2: ...ects enter the scale Be sure to select the suitable transformer whose output is DC 9V 400ma please use a separate power socket and the transformer delivered by the scale manufacturer in order to avoid...

Page 3: ...sted of 5 components and they must be assembled together before being used 2 First assemble four sides of windshield A B by inserting A into B from top to bottom or from bottom to up 3 Place the assem...

Page 4: ...on specification of buttons and display window Button for Start Stop Button for zeroing It returns the weight to zero may return the value displayed on screen to zero position zeroing range is 2 of th...

Page 5: ...Press down button to shift the weighing units Caution the symbol of weighing unit will flash when the weight becomes unstable during the weighing 3 2 Specification of counting function 1 Under the wei...

Page 6: ...ntity place the article whose quantity is the same with the selected one on the scale pan and press down button to begin sampling when the sound bi is heard and SE is disappeared the sampling process...

Page 7: ...then press down button to select Internal option Procedure 3 After completing the modification of internal options press down button to exit in case the next option should be set press down button to...

Page 8: ...ed may be cancelled temporarily Press down button to select ON OFF and complete the setting Ozt TROY OUNCE ON in use or OFF not in use Dwt PENNY WEIGHT ON in use or OFF not in use MM JPN ON in use or...

Page 9: ...ime AU 60 Auto Stop 60 min later 2400 4800 Setting of RS 232 transmission function Note Selection of transmission speed 9600 d 0 No limitation of zero display d 1 In case the indication is below zero...

Page 10: ...ff Auto backlight off No backlight Backlight mode of display window Note there are three backlight modes that may increase effectively the convenience of application on Backlight keeps ON Pr co Signal...

Page 11: ...rocedure 1 Under Stop mode first hold down button then press down button once to energize the scale and then release button Count Procedure 2 Press down button to enter calibration mode CAL Procedure...

Page 12: ...cale and then release all pressed buttons L CAL Procedure 2 After clearing away the scale pan press down button to enter zero calibration On0 Procedure 3 After the sound bi is heard place the weight e...

Page 13: ...right of SNUG III pin 2 is for signal output and pin 5 is for grounding and other pins are in reserve BAUD RATE 2400 OR 4800 OR 9600 bps DATA BIT 8 PARITY BIT N NONE STOP BIT 1 CODE ASCII BIT FORMAT L...

Page 14: ...ial transmission speed should be set correspondingly USB peripheral devices should be used as follows 1 Connect this electronic scale to a computer with USB line and then start the electronic scale in...

Page 15: ...t Err5 The weight of an article exceeds the maximal capacity 9e Remove the over heavy article from the pan promptly and avoid the similar error from then to avoid the possible damage Err6 The weight f...

Page 16: ...we beg your pardon for this 1 You fail to show the warranty of products or the writing of the warranty is too illegible to be discerned 2 The damage of scale is due to the abnormal or incorrect appli...

Reviews: