IO-9
Jade Range LLC
– A Middleby Company
Titan
TM
Series Heavy Duty Range
Model Series JTRH & JTRHE
CAUTION
When appliance is installed without legs or casters,
it must be set on a non-combustible curb or platform
with a minimum front projection of 4 1/2" over the
curb or platform. Leveling bolts (5/8-11) can be
used in the bottom frame of the range. If plumbing
and electrical connections allow, standard oven
u n i t s c a n b e i n s t a l l e d f l u s h t o a N O N -
COMBUSTABLE rear wall.
NOTE:
Convection models NOT recommended
for curb or platform installation also require
minimum 2” clearance at rear of unit
LEVELING
Appliances can be leveled with provided 6" high
adjustable legs or in curb or platform installations
(with the legs/casters removed) using 5/8-11
leveling bolts. Attachment points are located inside
the body of the unit at the front and rear of the
control box area and inside the combustion area
bottom on the right side of the inner body.
Adjust leveling legs or leveling bolts in base plate
until the appliance is level left to right and front to
back. Re-check and re-level in both directions until
the appliance is level in all directions.
NOTE:
For units with a “griddle”, the griddle plate
must be re-leveled independently from the body.
The rear corner of plate opposite the drain must
be slightly higher (1/8"). See illustration below for
location of griddle leveling bolts.
Leveling Bolt
Figure 5: Griddle Leveling Bolt Location
GAS LINE AND REGULATOR
INSTALLATION
A gas pressure regulator is required for all
installations. For single appliance installations, a
3/4"
regulator is supplied. Other size regulators
are available as options for larger pipe diameters.
In all cases, the feed line should never be smaller
than the inlet pipe of the unit. For proper operation,
the gas regulator should be installed horizontally,
in a accessible cool zone and protected from
grease and debris. Install the gas line with an
individual shutoff valve for servicing and code
requirements.
NOTE:
In Battery and Waldorf installations where
a main gas feed is branched to multiple appliances,
pipe size and gas regulator should be calculated
to provide a flow rate sufficient for all burners on
all appliances to operate simultaneously.
CAUTION
Do not use domestic flexible gas lines to install
this product!
NOTE:
Use a pipe joint compound that has been
approved for use with liquefied petroleum gases.
Pressure Adjust
under cap
(if adjustable)
In-Line Pressure Regulator
Figure 6: Gas Regulator Installation
Gas Line Pressure Testing
If the gas system is pressure tested at any pressure
equal to or greater than ½ psig (14" W.C./ 3.45
kPa), the appliance must be isolated from the
system by closing the gas shutoff valve. In Battery
or Waldorf installations, each appliance must have
its shutoff valve closed.