background image

IO-8

Jade Range LLC 

– A Middleby Company

Titan

TM

 Series Heavy Duty Range

Model Series JTRH & JTRHE

HI-SHELF /RISER INSTALLATION

1.

Remove the existing riser from the unit.

2.

Slide the riser support assembly into the back
of appliance as shown in the illustration below.

3.

Slide the riser support assembly toward the
front of the range.

4.

Install the bolts through the slots with washers
as shown.

5.

Tighten all bolts securely.

6.

Slide stainless steel shroud over riser support.

7.

Install rear panel and tighten securely.

8.

Install the flue diverter.

  

 

  

Figure 4: Installing Hi-Shelf/Riser

MOUNTING SALAMANDER OR

CHEESEMELTER

 CAUTION

Salamander (JSB model) and Cheesemelter
(JCM model) models require a “reinforced” riser
for range mounting.

F o r   t h e   i n s t a l l a t i o n   o f   a   s a l a m a n d e r   o r
cheesemelter on the riser of a Titan appliance,
please refer to the Installation and Operation
manual provided with the accessory unit.

Order the range mount and interconnect gas line
kit (optional) to install these units.

INSTALLATION CODES AND

STANDARDS

Installation of TITAN series appliances must
comply with all local and national building codes
for gas and electrical installations. See ANSI
Z233.1-1988, ANSI 233.1/NFPA 54, ANSI/NFPA
70-1990 or latest for specifications. All installation
or service work should be performed by qualified
personnel. (see explanation of qualified personnel
at the beginning of this manual).

ELECTRICAL INSTALLATION

WARNING

E L E C T R I C A L   A N D   G R O U N D I N G
C O N N E C T I O N S   M U S T   C O M P L Y   W I T H
APPLICABLE PORTIONS OF THE NATIONAL
ELECTRICAL CODE ANSI/NFPA-70 (LATEST
EDITION) AND LOCAL CODE REQUIREMENTS.

WARNING

T H E   R A N G E   M U S T   B E   E L E C T R I C A L L Y
GROUNDED IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE AND LOCAL
CODE REQUIREMENTS.

For convection ovens, provide an electrical outlet
capable of supplying 115 volts 60HZ 1 Phase for
1/4 HP blower motor. Blower motor amp draw is
4.4 amps/8 amp surge.

WARNING

THIS APPLIANCE IS EQUIPPED WITH A THREE
PRONG (GROUNDING) PLUG FOR USER
PROTECTION AGAINST SHOCK HAZARD AND
SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED THREE PRONG
RECEPTACLE. DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THE PLUG.

Clearances from Combustible Materials

Side

Rear

Floor

With 6" legs

10"

6"

6"

or 5" casters

(24.4 cm)

(15.24 cm) (15.24 cm)

installed

Clearances from Noncombustible Materials

With 6" legs

0"

0"

0"

or 5" casters

(0 cm)

(0 cm)

(0 cm)

installed

Summary of Contents for JTRH Series

Page 1: ...CTS JADE RANGE LLC RESERVES THE RIGHT TO CHANGE MATERIALS AND SPECIFICATIONS WITHOUT NOTICE JADE RANGE EQUIPMENT IS BUILT TO COMPLY WITH APPLICABLE STANDARDS FOR MANUFACTURERS INCLUDED AMONG THOSE APP...

Page 2: ...isdiction Reference National Electric Code ANSI NFPA No 70 latest addendum JADE TITAN SERIES RANGE S MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL...

Page 3: ...STALLATION CODES AND STANDARDS 8 ELECTRICAL INSTALLATION CONVECTION MODELS ONLY 8 Clearances from Combustible Materials 8 LEVELING 9 GAS LINE AND REGULATOR INSTALLATION 9 Gas Line Pressure Testing 9 G...

Page 4: ...center behind the kick plate beneath the oven door If gas orifices or regulator types gas or propane are changed in the field the rating plate must be changed to reflect the new orifice or gas type A...

Page 5: ...er Rear only Robata Satay 35 000 BTU per burner 2 IR burners per grid section French Top Range 30 000 BTU per burner 1 for each top section Char Broilers 15 000 BTU per burner 1 every 6 of broiler wid...

Page 6: ...xercised in leveling all appliances to the same plane This is important so that the 1 1 4 gas manifolds located at the front of each appliance can be connected via plumbing unions Failure to level all...

Page 7: ...ndum Z21 69189 with a quick disconnect device approved for gas fuel ANSIZ21 41 In addition a secure method of limiting the movement of the appliance must be provided to protect the connector gas line...

Page 8: ...with all local and national building codes for gas and electrical installations See ANSI Z233 1 1988 ANSI 233 1 NFPA 54 ANSI NFPA 70 1990 or latest for specifications All installation or service work...

Page 9: ...slightly higher 1 8 See illustration below for location of griddle leveling bolts Leveling Bolt Figure 5 Griddle Leveling Bolt Location GAS LINE AND REGULATOR INSTALLATION A gas pressure regulator is...

Page 10: ...factory occasionally onsite fine tuning may be necessary see below for proper burner flame adjustment Flame Characteristics for a Properly Adjusted Burner A correctly adjusted burner produces a flame...

Page 11: ...may have a slight yellow tip however the yellow tip should be no greater than 10 the overall flame size as shown in Figure 7 B Figure 9 Top Burner Air Shutter Adjustment Oven Griddle and Hot Top Burn...

Page 12: ...Top Controls Conventional Controls 1 Check that pilot lights are lit 2 Turn valve to ON position Burner will light 3 Adjust to desired heat 4 To turn off move control to the OFF position Griddle Top C...

Page 13: ...e sure oven door is closed 7 Turn the oven thermostat to desired temperature setting and turn the oven gas valve to ON Oven will light 8 Verify that the pilot light is still on 9 Turn oven gas valve t...

Page 14: ...o the desired temperature 4 Turn fan switch to AUTO This will turn on the fan 5 Allow oven to pre heat to the desired temperature 12 16 minutes 6 Open oven door Fan will automatically stop 7 Place pro...

Page 15: ...s When the oven has cooled place the product into the oven close the door and set the Blower toggle switch to the AUTO position Use of Oven Without Blower Fan It may be desirable for certain products...

Page 16: ...food splatter and condensed vapors that have baked on the appliance apply cleanser to a damp cloth or sponge NEVER RUB WITH A CIRCULAR MOTION To avoid marring the stainless steel finish rub as gently...

Page 17: ...nd wash drip pan under burners Brush burner head with a stiff wire brush Clean clogged ports with a stiff wire or ice pick Remove excessive grease build up from burners by soaking in a solution of was...

Page 18: ...st once a year This schedule is not meant to imply that a service company needs to be hired at the recommended intervals Someone with basic mechanical knowledge supervisor or manager should check and...

Page 19: ...r direct contact to infrared burners is not covered Exclusions JSB and JCM units mounted over open broilers are warranted for a period of Thirty 30 days from date of original installation Convection o...

Page 20: ...lled operated and maintained as follows 1 Installed in accordance with all local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 Latest Addenda 2 Installed u...

Reviews: