IO-4
Jade Range LLC
– A Middleby Company
Titan
TM
Series Heavy Duty Range
Model Series JTRH & JTRHE
INTRODUCTION
UNPACKING / INITIAL INSPECTION
This appliance was inspected before leaving the
factory. After unpacking, inspect the unit for any
damage that may have occurred during shipping.
**The transportation company assumes all
responsibility for safe delivery. If the appliance is
found to be damaged, save all packaging materials
and contact the carrier within 7 days of delivery.
Move the appliance as close as possible to
installation location. Remove all boxes and
packaging material from inside of oven. Remove
all shipping banding from pallet and top of range.
Remove all tops and oven components from their
boxes.
GENERAL
Jade Titan ranges are manufactured for use with
natural or propane gas. The gas type for each
range and the BTU rate is listed on the name
plate. Verify the unit is for the correct gas type
before installing it, by reading specifications on
appliance rating plate. Please read the installation
instructions carefully. Proper installation is
essential for safe and trouble free operation of this
appliance.
DATA PLATE LOCATION
Remove the kick plate. The data plate is located
to the right of center (behind the kick plate) beneath
the oven door. If gas orifices or regulator types
(gas or propane) are changed in the field, the
rating plate must be changed to reflect the new
orifice or gas type. All work should be performed
by a licensed and qualified professional.
150
200
250
300
350
400
450
500
550
L
O
R
O
A
S
T
BA
KI
NG
WARNING
WHEN MAIN GAS TO THE
APPLIANCE IS OFF, POWER
ON SWITCH MUST BE OFF.
TURN OFF ELECTRIC & GAS
TO APPLIANCE BEFORE
SERVICING ALL CONTROLS.
WARNING
THERMOSTAT
WHEN MAIN GAS TO THE
APPLIANCE IS OFF, POWER
ON SWITCH MUST BE OFF.
Figure 1: Data Plate
LOCATION
Locate appliance in an area that will make it easy
to load and unload the oven and will facilitate the
movement of food orders. Read Ventilation
Requirements in the Installation portion of this
manual before locating the appliance.
WARNING
THE EQUIPMENT AREA MUST BE KEPT FREE
A N D C L E A R O F A N Y C O M B U S T I B L E
MATERIALS.
GAS CONNECTIONS
Titan ranges are supplied with a 1-1/4" front manifold
and a 1" rear tailpipe. For rear connection, remove
cap. Ranges are supplied with 3/4" gas pressure
regulator. Operating pressure is 5.0" W.C. for natural
gas or 10.0" W.C. for propane gas.
**Maximum incoming pressure is 14.0" W.C.(1/2 psi
3.45 kPa)
NOTE: Gas Pressure Regulator must be installed
in an accessible “cool zone” protected from grease
and debris.
NOTE: Use a pipe joint compound that has been
approved for use with liquefied petroleum gases.