background image

16

Q

it is also possible yo use a smartphone or tablet computer, 

which interfaces via a wireless network (WLAN/Wi-Fi):

wi-fi

sc

sim

SMS

In any case, you must use an Ethernet socket (RJ-45), as indicated 
in position 

8

, to which the cable (length: ~ 5 m) coming from the 

remote control system, must be connected.

Q

The remote control system (to be installed in the appliance 

equipment zone) allows for the management of a maximum of 
10 modules (max. 5 saunas and max. 5 hammams).
  The cable connecting one module to another must not be longer 
than 500 metres 

(in such a case, you may need to install another re-

mote control system, in order to reduce the length of the cable section)

.

Q

Thanks to a SIM card, the Sasha remote control system sends, 

via short SMS messages, warnings with regards malfunctions to 
a specified mobile telephone; the card (not supplied) must be in-
serted to the remote control system during installation.
  We advise you check the cover offered by your mobile tele-
phone operator.

NOTE:

 It is not possible to manage the control system via SMS.

With regards the management and configuration of the connection 
network (LAN, WLAN, Wi-Fi, etc..), we recommend that you consult 
a technical expert in the subject.

Electrical safety

Sasha is a safe appliance, manufactured according to regulations 

EN 60335-1, EN 60335-2-105, EN 60335-2-53, EN 61000, EN 
55014-1, EN 55014-2

 and tested during production to guaran-

tee user safety.

Q

Installation must be carried out by qualified and authorized 

personnel, in compliance with the national provisions in force.

  

It is the installer’s responsibility to select the materi-
als, considering the way they will be used; to carry out 
the installation correctly; and to verify the condition 
of the network to which the system will be connected 
and its capability to ensure safety in maintenance 
and inspection operations.

 

Q

Class “

1

” appliances must be immutably connected, 

without 

intermediate junctions,

 to the electrical mains and protection 

circuit (ground system).

   

The building’s electrical system and ground system 
must be efficient and must conform to legal regula-
tions and specific national standards.

   

Where required, appropriate devices must be provided, 
which form part of the fixed system, and installed in 

compliance with current legislation in force, with the 
purpose of disconnecting the appliance from the mains 
(see also “Electrical connections arrangement”).

Q

For connection to the electric mains, you will need to in-

stall one or more isolating multi-pole switches, which will 
ensure complete disconnection in the instance of a category 
III over voltage; these devices must be connected to an area 
that complies with the safety regulations governing bath-
room safety.

  

Switches and electrical devices, according to regulations, 
must be connected to areas out of the user’s reach.

Q

The installation of electrical devices and equipment (sockets, 

switches, etc.) in the bathroom must be in compliance with legal 
standards and regulations in the country where the appliance is 
installed.

  

If the building’s electrical system is not able to guaran-
tee a stabile power supply, it is recommended to install 
a voltage stabiliser that suitably dimensioned for the 
required power upstream of the equipment.

Q

To connect the building’s electrical system, you must use a 

cable protected with a sheath with characteristics not inferior to 

H 07 RN-F

 and with a suitable cross section 

(220-240 V ~: min. 

6 mm2; 380-415 V 3N ~: min. 2.5 mm

2

).

   

The building’s electrical system must be equipped 
with a 0.03 A differential switch.

Q

In order to carry out the equipotential connection as specified 

in the specific national standards, the installer must use the ter-
minals provided on the frame of the 

“shower”

 module and on 

the 

“hammam”

 module, identified by the symbol  . 

In particular, it is necessary to ensure that all the surrounding 
metal masses are equipotential. (standard 

EN 60335.2.105

).

Q

The appliance is equipped with an LED lighting system in 

compliance with Norm 

EN 62471

; lamp rating: exempt Group.

Do not look directly at the light using optical devices (bin-
oculars, cameras, magnifying glasses).

Summary of Contents for sasha

Page 1: ...sasha sasha 2 0 Scheda di preinstallazione Pre installation sheet Fiche technique de pr installation Vorinstallationsblatt Ficha t cnica de preinstalaci n SAUNA HAMMAM...

Page 2: ...draulicheedelettriche 9 10 predisposizionedelloscarico 11 12 schemadellaposizionedeisupporti telaio 9 caratteristichetecniche 10 info 11 modalit d installazione 11 predisposizione dello scarico 12 pre...

Page 3: ...ci ndelossoportesdelarmaz n 13 caracter sticast cnicas 14 informaci n 24 Modalidades de instalaci n 24 Predisposici n del desag e 25 Predisposiciones de las conexiones hidr ulicas 25 Predisposiciones...

Page 4: ...4 302 5 W P 62 62 101 x 54 177 x 54 177 x 54 210 225 205 min 250 211 50 50 85 182 182 140 146 5 mm 210 210 1 W cm SAUNA HAMMAM...

Page 5: ...5 mm 302 5 cm 12 mm 5 mm SAUNA W SAUNA air air air air air air air a centro parete wall mounted au centre de la paroi in derWandmitte en centro de pared rif a a centro parete wall mounted au centre d...

Page 6: ...m 302 5 cm 302 5 cm W 302 5 cm 5 mm P 12 mm 5 mm W 12 mm 5 mm W SAUNA air air air air air air air a centro parete wall mounted au centre de la paroi in derWandmitte en centro de pared rif c ad angolo...

Page 7: ...Hz 220 240V 50 60 Hz 2H 380 415V 3N 50 60 Hz 220 240V 50 60 Hz 2S X X 1 2 M 5H X X X X X H H1 H2 O X 10 180 L 400 MAX 90 100 5S 2H 5H 90 80 8 8 8 3 3 2S 1 2 M H2 O 5S X 50 70 230 250 50 cm rif a rif c...

Page 8: ...8 1 1a H1 H X 2 cm X X X X X X X X H1 H 30 100 25 28 20 10 10 30 30 15 2 15 5 H H1 1a 1 40mm 175 X 3 5 m m cm rif a rif c rif d d1 rif b SAUNA HAMMAM...

Page 9: ...150 4 5 35 35 35 195 35 15 31 4 5 73 73 150 2 16 4 5 35 35 35 195 35 15 31 4 5 73 73 150 73 73 150 3 5 m m 3 5 m m posizione supporti telaio frame support position position supports ch ssis Position d...

Page 10: ...BATH SAUNA HAMMAM SAUNA DAMPFBAD SAUNA BA O TURCO SAUNA kW 4 6 6 j 4 5 j KIT AUDIO AUDIO KIT KIT AUDIO AUDIO SET KIT AUDIO W 100 j optional en option Zubeh r opcional GRUPPO LUCI LIGHTING GROUPE D CL...

Page 11: ...stallare un pannello per chiude re la zona frontale dell apparecchiatura tra cornice di finitura e soffitto si deve assolutamente garantire l areazione richiesta sia per la sauna che per l ham mam non...

Page 12: ...collegato nella cassetta dell apparecchia tura e lungo circa 400 cm come indicato in pos 2S Tale interruttore deve essere collocato in una zona che rispetti le prescrizioni di sicurezza imposte dalle...

Page 13: ...in modo permanente senza giunzioni intermedie alla rete elettrica ed all impianto di protezione impianto di terra L impianto elettrico e quello di terra dell immobile devono essere efficienti e confo...

Page 14: ...ay Should you wish to install a panel to close off the front area of the appliance between the covering frame and the ceiling you must ensure adequate ventila tion for the sauna and the hammam as inst...

Page 15: ...400 cm in length already connected to the appliance s junction box as indicated in position 2S This switch must be connected to an area that complies with the safety regulations as specified by curre...

Page 16: ...nd protection circuit ground system The building s electrical system and ground system must be efficient and must conform to legal regula tions and specific national standards Whererequired appropriat...

Page 17: ...souhaiterait installer un panneau pour fermer la zone frontale de l appareil entre cadre de finition et plafond il faut absolument garantir l a ra tion aussi bien pour le sauna que pour le hammam requ...

Page 18: ...vec c ble d j raccord dans le bo tier de l appareil et d environ 400 cm de longueur comme indiqu la pos 2S Cet interrupteur doit etre install dans une zone respectant les prescriptions de s curit impo...

Page 19: ...diaires l alimentation lec trique et l installation de protection mise la terre L installation lectrique et de mise la terre de l habi tation doivent tre en parfait tat et conformes aux dispositions...

Page 20: ...allieren m chten um den vorderen Bereich des Apparates zu verschlie en zwi schen Abdeckrahmen und Decke muss in jedem Fall die erforderliche Bel ftung garantiert sowohl f r die Sauna als auch f r das...

Page 21: ...arates ange schlossen und zirka 400 cm lang ist wie gezeigt in Pos 2S Dieser Schalter muss in einem Bereich untergebracht werden der die Sicherheitsvorschriften der geltenden Norm erf llt Q Jedes Hama...

Page 22: ...die Netzinstallation und die Erdungsanlage vorgeschrieben Die elektrische oder die Erdungsanlage m ssen ein wandfrei funktionst chtig sein und den geltenden gesetzlichen Vorschriften und spezifischen...

Page 23: ...auna En caso de que fuera necesario instalar un panel para ce rrar la zona central del equipo entre el marco de acaba do y el techo se debe garantizar la ventilaci n necesaria tanto para la sauna como...

Page 24: ...ye un cable ya conectado en la caja del equipo con una lon gitud de aproximadamente 400 cm como se indica en la pos 2S Este interruptor debe colocarse en una zona que respete las indi caciones de segu...

Page 25: ...e 1 debe conectarse de modo permanente sin uniones intermedias a la red el ctrica y a la instalaci n de protecci n toma de tierra La instalaci n el ctrica y la toma de tierra del inmueble deben ser ef...

Page 26: ...26 Q a P1 P P1 P W b c P W b W c Q d d1 P1 P W Jacuzzi P 22 25 C 250 c Pr 1 2 Pr 1 5 mm MAX Pr 2...

Page 27: ...1 2 M 5S Q IEC 60335 1 A2 600 a 6 Q 220 240 1 380 415 3N 220 240 1 380 415 2N 380 415 3N Q 220 240 Q 220 240 Q 400 c 2S Q 2H 4 6 6 380 415 4 6 6 3 Q Q H 05 VV F 2x2 5 2 220 240V 2A Q 3 Q 8 20 x 4 Q 1...

Page 28: ...RJ 45 8 5 Q 10 5 5 500 Q SIM Sasha SMS SMS LAN WLAN Wi Fi Sasha EN 60335 1 EN 60335 2 105 EN 60335 2 53 EN 61000 EN 55014 1 EN 55014 2 Q Q 1 Q III Q Q H 07 RN F 220 240 V min 6 mm2 380 415 V 3N min 2...

Page 29: ......

Page 30: ...l A Company of Jacuzzi Brands Corp USA Jacuzzi Bathroom Espa a C Comte urgell 252 local 4 08036 Barcelona Phone 34 932 385 031 Fax 34 932 385 032 www jacuzzi es info es jacuzzi eu I dati e le caratter...

Reviews: