Drainage system
Two drainage pipes are provided.
- We recommend connecting the two drainage pipes so that you
are left with one drainage outlet, as indicated in positions
1 or 1a
.
It is also possible to independently connect the drainage pipes
to the drainage system.
In all cases, you must ensure that the drainage pipe fittings are
routed to the floor, as indicated, whilst bearing in mind the posi-
tioning of the frame supports (feet).
Hydraulic connections
Q
For connection to the water supply (
5H
- hammam) we advise using
pipes with min Ø 14 mm; these pipes must have a 1/2” M pipe joint.
Q
The
“sauna”
model is equipped with an automatic filling tank
which must be powered by a a 1/2” M (cold water) pipe joint (po-
sition
5S
).
Q
In order to ensure correct operation, the pressure and flow
rate values must also comply with the values specified in the rel-
evant “Hydraulic specifications”.
Where “hard” water is present, it is advisable to install
a decalcifier in the water system supplying water to the
appliance, in order to reduce and/or avoid calcareous
deposits.
ATTENTION: (IEC 60335-1/A2) The pressure of the wa-
ter system supplying water to the appliance must not
exceed 600 k Pa (6 bar).
Electrical connections
Q
The electrical connection can be made in one of the following ways:
sauna
- single-phase line (220-240V 1~);
- three-phase line consisting of three phase cond
neutral conductor (380-415V 3N~).
hammam
- single-phase line (220-240V 1~);
- three-phase line consisting of two phase cond
neutral conductor (380-415V 2N~);
- three-phase line consisting of three phase cond
neutral conductor (380-415V 3N~).
Q
The rated power supply voltage of the equipment is
always 220-240V.
Q
The equipment can also be installed in countries where
the 220-240V voltage is supplied by a two-phase system. For
the connection please refer to the instruction manual.
Q
Each “
sauna
” is equipped with a multiple-pole switch, complete
with a cable, approximately 400 cm in length, already connected
to the appliance’s junction box, as indicated in position
2S
.
This switch must be connected to an area that complies with the
safety regulations as specified by current legislation in force.
Q
Each “
hammam
” is supplied with a quadripolar terminal block
located in the equipment zone; a cable must be connected to
this terminal block (position
2H
) ; the aforementioned cable
must be connected to an isolating multi-pole switch;this switch
must be connected to an area that complies with the safety reg-
ulations as specified by current legislation in force.
The steam generator, common to each
“hammam”
, can be
supplied with absorbed power equal to 4.6 kW or 6 kW. If
power is provided with a three-phase line (380-415 V ) and
you wish to limit the absorbed power to 4.6 kW, the ca-
ble which is to be connected to the terminal block should
only have two phases, in addition to the neutral and earth
wires. In the instance where the absorbed power is equal
to 6 kW, power must be provided by three phases, in addi-
tion to the neutral and earth wires.
Q
For guidance with regards to electrical connections,
please refer to the installation manual.
Q
Some models allow you to connect the appliance to an alarm
circuit (provided, in the area marked with the bell symbol), a
bipolar cable with characteristics not inferior to type H 05 VV-F
2x2.5 mm
2
(220-240V - 2A max.); this cable must be used in order
to ensure that the cable clamp attached to the box offers ad-
equate protection (water tight) as detailed by legislation.
Audio system
Q
“
Sauna
” and/or “
hammam
” are equipped with speakers* that
can be connected to a cable radio network; the relevant cable
must be arranged as indicated in position
3.
Q
Upon request, an audio kit is available, which can be installed in
the appliance’s appropriate equipment zone, to which the speak-
ers will also be connected.
NOTE:
(*
)
two+two speakers; impedance: 8 Ω - optimal power: 20 W x4.
Remote control system arrangement
(where present)
Q
it is possible to manage the “
sauna
” and “
hammam
” functions
using a computer which interfaces with a remote control system
(
sc
) via an Ethernet (LAN) network:
sc
LAN