![background image](http://html1.mh-extra.com/html/jacto/arbus-400/arbus-400_operators-manual_3181959050.webp)
4-50
4
OP
ER
A
TION
A
N
D
A
D
JU
ST
M
EN
TS
ARBUS 400
VDC cable control kit (Optional)
• Remove the control valve from the spray-
er. To remove it, loosen the two screws
and disconnect the hoses (A).
Assembling the control
• Mount the cable control valve bracket to
the control valve support of the sprayer
as shown in the figure below.
• Install the cable control valve on the
bracket.
• Remove the cylinder assembly from the
control valve removed from the sprayer (A).
• Mount the cylinder to the cable control
valve. Take care not do damage the pack-
ing rings.
• Connect the hoses again.
Cabel control valve bracket
VDC kit
detalhe A
OBSERVATION:
When disconnecting the hoses,
note their position so as to con-
nect them again correctly when
installing the VDC CABLE CON-
TROL KIT.
OBSERVATION:
The hose (pressure hose) that con-
nects the control valve to the pump
must be replaced by the hose of
the VDC CABLE CONTROL KIT.
A
B