6 CONTROLS
29
6.2.7 JOYSTICK _______________________________________________________________
The joystick controls the cutting units lift and lower. The joystick operates in
automatic or manual mode. Push the joystick to lower the cutting units or pull the
joystick to lift the cutting units.
Manual Mode - Set the PTO switch in the OFF (down) position to set the joystick
in manual mode. When in manual mode, cutting units lift or lower only while
pressure is applied to the joystick.
Automatic Mode - Set the PTO switch in the ON position to set the joystick in
automatic mode. Push and release the joystick to lower the cutting units to the
ground and the cutting unit reels will start to turn when forward motion starts. Pull
and release the joystick to lift the cutting units to the crosscut position and the
cutting unit reels will stop. To lift the cutting units to the transport position, pull and
hold the joystick until cutting units are completely lifted.
When forward movement is stopped, the reels will stop. When forward motion is
started again, push and release the joystick to restart the reels.
6.2.8 ALARM __________________________________________________________________
The alarm located below the armrest indicates the condition of the mower or to get the
attention of the operator and persons near the area of operation. These conditions will cause
the alarm to sound:
•
The temperature of engine coolant is more than 230° F (110° C)
•
The hydraulic fluid level is low
•
The engine oil pressure is less than 7 psi (0.48 BAR)
•
The horn switch is in the ON position.
•
The water separator needs to be serviced.
•
The alarm will sound for one second when the mower is started.
•
A fault sensed by the controllers. The fault message is shown on the LDU.
6.2.9 12 VOLT ACCESSORY OUTLET______________________________________________
The 12 Volt accessory outlet found inside the armrest storage tray supplies
power to 12 Volt accessories. Only use the 12 Volt outlet with the engine
started to prevent a drained battery.
CAUTION
The 12 Volt accessory outlet is protected by a 10-Amp fuse. Do not use
attachments with a power rating greater than 120 watts.
To prevent the risk of burns or fire, do not replace the 10-Amp fuse with a
fuse with a greater amperage rating.