23
PLC TROUBLESHOOTING
MAINTENANCE
1. Line C displays the number of cycles since the last "flush" or complete tub drain.
2. Line D shows the number of cycles that perform before the "flush" light activates.
• Press + or - to highlight line D.
• Press OK to enter highlight mode.
• Press + or - to make any adjustments needed.
* Flush Setpoint: 5 to 30
• Press OK to confirm adjustments.
• When flush light is activated, user should remove the standpipe and drain the tub.
SCREEN 9:
WASH CYCLE COUNT
RINSE TANK TEMPS:
TOP: 00187F
BOTTOM: 00178F
Millenium 3
Crouzet
1. Line C shows the current temperature reading of the top booster tank.
2. Line D shows the current temperature reading of the bottom booster tank.
A
B
C
D
SCREEN 8:
RINSE TANK
TEMPERATURES
The "Rinse Tank Temperatures" screen allows the user to see the temperature
readings in the top and bottom rinse tanks.
Not applicable for AVENGER LT-E Models.
The "Wash Cycle Count" screen allows the user to see the number of cycles since
the last complete tub drain and edit the number of cycles that perform before the
"flush" light activates.
WASH CYCLE COUNT:
CURRENT COUNT: 01
FLUSH SETPOINT: 05
Millenium 3
Crouzet
A
B
C
D
Summary of Contents for AVENGER HT-E
Page 2: ......
Page 35: ...29 CONTROL PANEL PARTS 1 8 3 2 4 5 6 7 ...
Page 41: ...35 115V CONTROL BOX PARTS ITE 2 3 4 5 6 7 8 9 13 14 15 4 4 2 5 6 8 9 7 3 1 1 ...
Page 46: ...40 WASH DRAIN MOTOR ASSEMBLY PARTS 10 11 12 13 1 2 3 4 5 9 8 6 7 ...
Page 54: ...48 RINSE TANK ASSEMBLY PARTS 8 7 6 5 2 3 4 1 ...
Page 58: ...52 SCHEMATICS 115 VOLT ELECTRICAL DIAGRAM ...
Page 59: ...53 SCHEMATICS 208 230 VOLT ELECTRICAL DIAGRAM ...