background image

Contents:  

 

1

 

Limited warranty ........................................................................................................................ 2

 

2

 

Indicators.................................................................................................................................... 3

 

3

 

Controlling the system .............................................................................................................. 4

 

3.1

 

Arming ................................................................................................................................ 5

 

3.2

 

Disarming............................................................................................................................ 6

 

3.3

 

Panic Alarm ........................................................................................................................ 6

 

3.4

 

To stop ALARM................................................................................................................... 6

 

3.5

 

Home arming ...................................................................................................................... 7

 

3.6

 

Door opening ...................................................................................................................... 7

 

3.7

 

Alarm memory reading ........................................................................................................ 7

 

3.8

 

Split system arming ............................................................................................................. 7

 

3.9

 

Subsystem arming .............................................................................................................. 8

 

3.10

 

Appliance control ................................................................................................................ 8

 

4

 

User’s settings ........................................................................................................................... 8

 

4.1

 

New master code ................................................................................................................ 8

 

4.2

 

User codes setting .............................................................................................................. 9

 

4.3

 

Internal clock setting ........................................................................................................... 9

 

4.4

 

Automatic arming / disarming ............................................................................................ 10

 

4.5

 

Bypass .............................................................................................................................. 10

 

5

 

Digital communicator .............................................................................................................. 11

 

5.1

 

JA-60GSM Dialer module.................................................................................................. 11

 

5.2

 

JA-65X Telephone communicator ..................................................................................... 11

 

5.2.1

 

Telephone numbers for voice message sending ....................................................... 11

 

5.2.2

 

Telephone communicator testing .............................................................................. 12

 

6

 

System testing ......................................................................................................................... 12

 

7

 

Battery replacement ................................................................................................................. 12

 

8

 

Enrollment of the control panel to UC-2xx modules .............................................................. 13

 

 

1  Limited warranty 

 

Subject to the conditions of this Limited warranty Jablotron Ltd. warrants this product to 

be free from defects in design, material and workmanship at the time of its original 

purchase by a customer for a subsequent period of two (2) years. Should your Product 

need warranty service, please return it to the dealer from whom it was purchased. 

 

Conditions:  

 

1.  The warranty is valid only if the original receipt issued to the original purchaser by 

the dealer, specifying the date of purchase, is presented with the Product to be 

repaired or replaced. Jablotron reserves the right to refuse warranty service if this 

information has been removed or changed. 

2.  This warranty does not cover any failure of the Product due to misuse, including 

but not limited to use in other than the normal  and customary manner, in 

accordance with instructions for use and maintenance of the Product. Nor does 

this warranty cover any failure of the product due to accident, modification, 

adjustment, improper repair or acts of God. 

3.  This warranty does not apply to batteries nor modules of other suppliers (e.g. SIM 

card of the GSM provider). 

4.  The warranty provided does not affect the consumer's statutory rights under 

applicable national legislation in force, nor the consumer's rights against the 

dealer arising from their sales / purchase contract. 

Alarm system JA-63 „Profi“ 

- 2 - 

MGK51504 

Summary of Contents for Profi

Page 1: ...JA 63 Profi User manual...

Page 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Page 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Page 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Page 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Page 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Page 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Page 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Page 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Page 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Page 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...