c.  multiple pressing and holding of the keys (2 or 3) will switch the 

bypass on – off – on – off …  

4.  By repeating step 3. you can bypass all required alarm sources. 

  To close the Bypass menu press the 

N

  key.  If anything is bypassed when 

arming, four beeps will sound and 

b

 will be displayed on the keypad during the 

exit delay (and partial arming will be recorded to the memory). 

  All bypasses selected with key 

2

 (next arming period bypasses) will switch off 

automatically with the first following disarming. 

  The existing bypass setting can be checked or modified in the bypass menu. 

  All bypasses can be deleted by key 

4

 in the bypass menu. They can also be 

deleted by the programming mode opening or if the control panel is 

disconnected from the power completely (AC & back up battery).  

 

To 

exit user mode

 press 

N

 

5  Digital communicator 

 

 

5.1 JA-60GSM Dialer module 

 

If the control panel is equipped with a JA-60GSM communicator, please look at 

the JA-60GSM user manual for details about user’s setting. 

 

5.2 JA-65X Telephone communicator 

 

If the control panel is equipped with a JA-65X telephone communicator and if 

the installer enabled the supervisor to modify the communications settings, only 

then will the following programming be possible.  

 

5.2.1  Telephone numbers for voice message sending 

 

Up to 4 telephone numbers can be programmed in the user mode. To switch the 

control panel to the user mode enter 

F 0 master  code

. User mode will be 

indicated by a 

U

 on the keypad.   

Store telephone numbers for voice message by entering: 

7 xx... xx F y

   

where 

  xx...xx

 = telephone number 

 

y

 = memory number from 1 to 4 

A telephone number can have a maximum of 16 digits. A dialing 

pause

 can be 

entered with 

F0 

 

Note:

  enter a pause (F0) after the last digit of a 

number, which is calling a 

mobile phone

. This way the number will be called only once and the dialer will 

not check the line signals (some mobile phone systems do not generate standard 

telephone line signals).  

 

Alarm system JA-63 „Profi“ 

- 11 - 

MGK51504 

Summary of Contents for Profi

Page 1: ...JA 63 Profi User manual...

Page 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Page 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Page 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Page 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Page 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Page 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Page 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Page 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Page 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Page 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Reviews: