3.9  Subsystem arming 

 

In a large building a sub control panel can be enrolled to the JA-63. The 

subsystem reports all alarms and failures to the main system.   

The installer can program if the systems will be armed and disarmed separately 

(by their own codes and remote controls) or if the main control panel will rule the 

sub control panel. Ask your installer for explanation on how to operate your 

system if a sub control is panel installed. 

 

3.10  Appliance control 

 

The system can be used to control an electrical appliance (light, heating, 

ventilation etc.). In such a case users can operate the device: 

 

Locally with keypad*

 – entering 

F81

 (ON) or 

F80

 (OFF).  

 

Remotely by phone keypad or by SMS messages

 – the control panel 

must be equipped with GSM communicator for this feature  

 

*

 

Installer can program that this feature will work only when the entry is followed by a user code.

 

4  User’s settings  

 

Following section is designated for the system supervisor, who knows the 

master code. 

All programming sequences can be terminated before completed (by 

N

 key). 

 

4.1 New master code 

 

 

The master code is used by the supervisor. The 

factory default 

master code is 

1234

 and you should program your own four digits code. Code programming is only 

possible when the system is disarmed. 

To change an existing master code enter: 

 

 F   5    xxxx    yyyy    yyyy  

 

where 

xxxx

 is the existing and 

yyyy

 is the new master code (new code must be 

entered twice to avoid an error).  

 

Example: 

Existing code 1234 will change to 6723 entering: 

F  5  1234  6723  6723 

Alarm system JA-63 „Profi“ 

- 8 - 

MGK51504 

Summary of Contents for Profi

Page 1: ...JA 63 Profi User manual...

Page 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Page 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Page 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Page 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Page 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Page 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Page 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Page 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Page 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Page 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Reviews: