Master code 

 

Is an extra (15

th

) access code for the supervisor. It can operate the system and it 

also allows for the programming of the other user codes and to enter the user mode 

(see section 4). 

 

Factory default

  master code is 

1234

. The supervisor should change it after 

installation. 

 

Service code 

 

Is an extra code, used by the installer to enter the programming mode. End users 

are not usually told this code.  

 

If an invalid access code is entered 

more than four times in a given period of 

time, it will trigger a Tamper alarm on the control panel.   

 

 

3.1 Arming 

 

On the keypad 

- enter your user code or press the fast arming button

*

 

 

On the remote control 

(RC-4x) – press the   button  

  

  system will beep once and the exit delay countdown will start 

  ARMED indicator will flash during exit delay

**

 

  you should leave the protected area within the duration of the 

exit delay  

 

If there are 

4 beeps while arming

, the system is indicating an unusual situation 

and the keypad will display the specific information:    

 

ALARM and a zone number

 – the zone is not ready (opened door etc.), 

check the indicated item. 

b

 – some detectors are bypassed (done by supervisor, see part 4.5)  

 

Note: 

supervisor can program an automatic arming for a desired time (for 

example, the house will be armed automatically at 21:00 if left disarmed). 

Automatic disarming is also programmable. See part 4.4 for details.

  

 

*

 Fast arming (without access code) can be disabled by the installer 

**

 The JA-60F battery powered wireless keypad will stop indications 10sec after the most recent  key 

entry. 

Alarm system JA-63 „Profi“ 

- 5 - 

MGK51504 

                                                      

Summary of Contents for Profi

Page 1: ...JA 63 Profi User manual...

Page 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Page 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Page 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Page 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Page 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Page 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Page 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Page 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Page 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Page 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Reviews: