Telephone line  indicated event (Tamper or Failure) was caused 

by the telephone line 

 

digital bus 

indicated event (Tamper or Failure) was caused 

by a device (keypad or PC) connected to the 

digital bus 

 

communication 

failure 

wireless keypad lost connection with the control 

panel 

 

error 

self testing error – call installer 

tab. 1 

 

88

 display specifies mode of the control panel: 

 

user mode 

authorized supervisor can test, bypass zones, change 

batteries, record voice messages, program tel. 

numbers and adjust internal clock in this mode

 

 

home arming 

system is partially armed – particular detectors are 

bypassed  (someone remains in the house) 

 

A section armed 

A section is armed (split system) 

 

B section armed 

B section is armed (split system) 

 

complete 

arming 

system is completely armed  

 

bypass 

warning that some detectors are bypassed – 

indicated while arming 

 

key pressed 

waiting for more data to complete the entry 

 

programming 

mode 

for installer programming and testing 

tab. 2

 

3  Controlling the system 

 

The system can by controlled by keypads, remote controls or by a PC with the 

Comlink Software. 

   

User codes   

 

Can be used to arm and disarm the system or to reset an alarm. There can be up to 

14 different user codes for individual  users. The system stores to its memory which 

code was used for which operation as well as the  time &date of usage. This data can 

go to a  Central monitoring station and can also be viewed using a  PC with Comlink 

software. All user codes are empty as a factory default and should be programmed by 

the supervisor (see section 4.2).  

Alarm system JA-63 „Profi“ 

- 4 - 

MGK51504 

Summary of Contents for Profi

Page 1: ...JA 63 Profi User manual...

Page 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Page 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Page 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Page 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Page 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Page 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Page 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Page 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Page 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Page 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Reviews: