jablotron Profi User Manual Download Page 6

 

3.2 Disarming 

 

On the keypad 

-

 

enter your user code 

 

On the remote control 

(RC-4x) – press the   button

 

 

  system will beep twice 

  if there are 3 beeps, important information is indicated and will 

be displayed on the keypad. Examples: 

o

 

FAILURE

 LED is flashing – press the N key to view  the cause  

o

 

ALARM 

LED and zone number is flashing = alarm in the memory. 

Be careful and check the house.

 

  if you enter the premises when the system is armed, the entrance delay 

countdown will start after you trigger a delayed detector (ARM LED will 

flash and beeps will sound if programmed so

*

).  

 

 

3.3 Panic Alarm  

 

If you are in danger you can trigger the silent panic alarm to inconspicuously call 

for help. While in Panic alarm mode the control panel can send a voice message, 

an SMS message and data to a central monitoring station via a telephone line 

(depends on installation settings). 

 

 

Panic alarm can be triggered: 

 

 

On the keypad

 - press the panic key and then enter your 

access code.  

On the remote control 

(RC-4x) - press the   and   buttons 

simultaneously. The remote control can be switched (by installer) to a 

Panic mode, in which pressing of any button will trigger the Panic alarm. 

  By 

pressing this large sized panic button, the

 RC-22 (can be installed 

on the wall, under a desk etc.). 

 

 

3.4 To stop ALARM 

 

If an alarm is triggered when you are present, you can 

stop it by entering your access 

code or by pressing button   on the remote control

 

  Sending of voice and SMS messages will cease after the alarm is stopped. All 

corresponding report codes (alarm triggering & stopping) will be sent to the 

central monitoring station. 

  If user does not stop the alarm, it will stop automatically after the programmed 

period and the alarm memory indicator will activate. The control panel will 

return to the same mode as before the alarm. 

Alarm system JA-63 „Profi“ 

- 6 - 

MGK51504 

Summary of Contents for Profi

Page 1: ...JA 63 Profi User manual...

Page 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Page 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Page 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Page 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Page 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Page 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Page 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Page 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Page 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Page 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Page 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Page 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Page 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Page 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Page 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Reviews: